Pump Installation - Efco SWAPLOADER SL-145 Parts And Operation Manual

Table of Contents

Advertisement

1.
Install the hydraulic pump to the P.T.O. (Bolts are not provided).
2.
Install the hydraulic fittings into ports on the hydraulic pump as shown on Drawing No.
90H91.
3.
Connect the suction hose assembly to the hydraulic tank (1" I.D. hose) and route to the
hydraulic pump in as short and straight line as possible. Be sure to route the hose clear of
exhaust components and of the drive shaft. Extra hose is provided so the hose can be
shortened to an appropriate length. Install the hose on the hose barb fittings at the tank
and at the pump and secure with the hose clamps provided.
NOTE: Prior to startup, this hose must be filled with oil.
4.
Connect pressure hose assembly (1/2 inch I.D. hose) to control valve inlet and route to
the pump the same as the suction line. This hose is provided with only one fitting, so the
5.
Tie up the pressure and suction hoses as necessary. Again, be sure the hoses are routed
to avoid exhaust components and to stay clear of the drive shaft.
SL-145.INS
09/2009

PUMP INSTALLATION

hose can be shortened to appropriate length. Remove the
hose and shorten as required. After the hose has been
shortened, lubricate the insert threads of the fitting and
the I.D. of the hose. Measure 1 3/16 inches from the end
of the hose and mark the hose for the socket depth.
Screw hose into the socket (left-hand thread) to the depth
marked on the hose. Screw insert in socket until insert
touches the socket. Clean the inside of the hose
assembly by either blowing clean compressed air through
it or by flushing it. Install the completed hose assembly
to the inlet port of the control valve assembly and the
outlet port of the hydraulic pump.
2-14