Toshiba RAS-07SKSX Service Manual page 42

Table of Contents

Advertisement

9-5-3. Outdoor unit does not operate
Shut off the power supply
from AC outlet once and turn
it on after 5 seconds.
Does the OPERATION lamp blink?
YES
Does the power turn on by pushing
the [START/STOP] button
of the remote control?
YES
Is AC 220-240V supplied between
terminal block 1 -
YES
Is cable connection between indoor
and outdoor units correct?
YES
Check items as following procedure
in 9-5-4, 9-5-5, 9-5-6
NO
NO
NO
?
2
NO
See "Power can not be turned on".
See "Power can not be turned on".
Relays (RY01)
Q16 or IC30 is failure.
Correct cabling between indoor
and outdoor units.
– 41 −
FILE NO. SVM-07021
Replace the
P.C. board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-07s2axRas-09sksxRas-09sasx