4-3. Outdoor Unit (RAS-09SASX)

No.
Parts name
1
Compressor
Fan motor
2
(for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
Type
Output (Rated) 780W, 2 poles, 1 phase, 220-240V~, 50Hz
QK164PBA
Winding resistance (Ω)
(at 20°C)
Output (Rated) 20W, 6 poles, 1 phase, 220-240V~, 50Hz
SKF-240-20B
Winding resistance (Ω)
(at 20°C)
DS451155NPQB
AC 450V~, 1.5µF
RS44B356U0215S
AC 440V~, 35µF
LPAP960B
U/T: 6.1A(80°C), Open: 135±5°C, Close: 75±11°C
− 9 −
FILE NO. SVM-07021
Specifications
C-R
3.51
Red-Black
White-Black
235.2
C-S
3.67
260.1