Toro 690 Series Installation & Service Instruction
Toro 690 Series Installation & Service Instruction

Toro 690 Series Installation & Service Instruction

Hide thumbs Also See for 690 Series:

Advertisement

Introduction
The 690 Series Rotary Sprinkler is designed for irrigation of large turf areas such as golf courses, parks,
recreational fields and school grounds.
Manufactured from durable, high strength engineering plastic and stainless steel components, the 690 sprinkler
incorporates many innovative and time proven features for lasting, maintenance-free operation. Some of these
features are listed below.
Model 69X-06-XX
Specifications
• 78 ft. – 108 ft. Radius
• Pop-Up Nozzle and Cap -
• 1
in. NPT Female Thread Inlet
1
2
• Recommended Operating
Pressure: 60 – 100 PSI
• Maximum Pressure: 150 PSI
• Electric Models:
– Solenoid - 24 VAC
– Inrush Current - .40 Amps
– Holding Current - .235 Amps
• Dimensions:
– Cap Diameter - 7
1
in.
2
– Flange Diameter - 10 in.
– Height - 16 in.
All manuals and user guides at all-guides.com
INSTALLATION & SERVICE INSTRUCTIONS
690 Series Rotary Sprinkler
Model 69X-01-XX
Features
• Positive Spring Retraction - Pulls nozzle and cap down out of the
way of people and turf maintenance equipment.
7
in.
8
• Three Nozzle Sizes - Multiple nozzle sizes provide 45.1 to 82.2 GPM
flow and produce watering radii from 78 to 108 feet.
• Long Life Gear Drive - Gear drive mechanism is vacuum-packed with
lubricant and isolated from water stream for long, trouble-free life.
• Valve-In-Head Models - Permits head-by-head control to customize
turf watering for various topography and soil conditions. Multi-cycle for
wind or runoff problems, frost control and dew removal without low-head
drainage. Available for hydraulic normally open or 24 Volt electric
systems.
• Sprinkler Operating Mode - Electric valve-in-head models have three
modes of operation; AUTO, ON and OFF. Mode is set using a selector
tool inserted through the sprinkler body flange.
• Built-in Check Valve - Check-o-matic sprinklers utilize a check valve in
the sprinkler base to prevent seepage from low area heads after valve
closure. Check valve will hold up to 35 feet of elevation differential.
• Two-Speed / 60°-120° Models - Provides for more even precipitation.
Runs at half speed in non-overlapping areas.
• Two-Speed / 180° Models - Provides for more even precipitation
where only a selected area is covered by an overlap, such as is found on
greens. Runs at half speed in non-overlapping areas.
• Serviceability - All internal parts of the sprinkler are accessible through
the top of the sprinkler body.
Model 69X-02-XX

Advertisement

Table of Contents
loading

Summary of Contents for Toro 690 Series

  • Page 1 690 Series Rotary Sprinkler Introduction The 690 Series Rotary Sprinkler is designed for irrigation of large turf areas such as golf courses, parks, recreational fields and school grounds. Manufactured from durable, high strength engineering plastic and stainless steel components, the 690 sprinkler incorporates many innovative and time proven features for lasting, maintenance-free operation.
  • Page 2: Model Number Code

    50% of diameter 8 m.p.h. 45% of diameter Installation Procedure To assure maximum performance from your 690 Series Rotary Sprinklers, read these instructions completely prior to installing or servicing the sprinkler. Construct Swing Joints 1. Construct triple swing joints for each sprinkler as shown in Figure 1.
  • Page 3: System Start-Up

    All manuals and user guides at all-guides.com Connecting Electric Control Wires Table 1 - Wire Sizing Chart Maximum Allowable Length in Feet From Controller to VIH Sprinklers. 1. Route control wires to sprinkler location(s). Provide enough extra wire at sprinkler to allow for VOLTAGE WIRE SIZE NUMBER OF VALVES...
  • Page 4: System Troubleshooting

    Another important function of the pilot valve is to regulate the water pressure to the sprinkler nozzle. Pressure regulation compensates for large variations within the system and maintains a constant pressure for optimum sprinkler operation. The 690 series pilot valve is factory set to regulate at 80 or 100 PSI depending on sprinkler model.
  • Page 5 All manuals and user guides at all-guides.com System Troubleshooting (continued) Sprinklers Possible equipment failures with causes and corrective action are listed below. PROBLEM POSSIBLE CAUSE – CORRECTIVE ACTION 1. Sprinkler won't rotate (a) Stator too large for nozzle - Use proper nozzle. (b) Debris wedged between stator and turbine - Remove obstruction.
  • Page 6: Servicing Procedures

    Servicing Procedures Introduction The 690 Series rotary sprinkler is designed to provide the user trouble free operation for many years without scheduled maintenance. Should it become necessary to disassemble the sprinkler to correct a malfunction or replace a component, all internal parts of the sprinkler are accessible from the top. Refer to the Troubleshooting Procedure in this manual in the event of a malfunction.
  • Page 7 All manuals and user guides at all-guides.com 13. To reinstall valve assembly with snap ring and to prevent damage to the communication tube in sprinkler body, use valve insertion tool (P/N 995-11). Valve insertion tool will automatically line up valve assembly with sprinkler body communication tube and correctly seat the snap ring.
  • Page 8 All manuals and user guides at all-guides.com Servicing Pilot Valve Assembly Note: Assure water supply to sprinkler is positively shut off and all residual pressure has been bled. If sprinkler is pressurized, main valve will open when the pilot valve control tube is disconnected. Refer to Figure 7 for the following procedure.
  • Page 9 All manuals and user guides at all-guides.com Figure 7 Pilot Valve, Current Item No. Part No. Nomenclature Quantity Per Assy. 89-1905 Solenoid, Pilot Valve & Valve 89-6005 Adapter, Pilot Valve, NC 89-0001 Housing, Pilot Valve 360-0220 O-Ring, .070" x .551" x .691" 35-9993 Plunger Assy., Elec.
  • Page 10: Model Number Information

    All manuals and user guides at all-guides.com Figure 8 690 Series Model Number Information 6 9 X - X X - X X X Body Nozzle Pressure Regulation * 1 = 90° Quarter Circle 01 = NPT, NO Valve-In-Head 8 = 80 PSI 2 = 180°...
  • Page 11 All manuals and user guides at all-guides.com Item No. Part No. Nomenclature Quantity Per Assy. 3-2518 Plug, Cap , Rubber 3-3567 Screw, Machine, 1/4 - 20 x3/8" 3-3529 Cap Assy., Rubber Cover (Includes Item 4) 3-3582 Cover, Cap, Rubber 3-3532 Cap, Blank 9-2734 Strap, Spring...
  • Page 12 All manuals and user guides at all-guides.com © 2001 The Toro Company, Irrigation Division • An ISO 9001-Certified Facility Form No. 366-0041 Rev. B...

This manual is also suitable for:

69-0669-0169-02

Table of Contents