System Start-Up - Toro 690 Series Installation & Service Instruction

Hide thumbs Also See for 690 Series:
Table of Contents

Advertisement

Connecting Electric Control Wires
1. Route control wires to sprinkler location(s). Provide
enough extra wire at sprinkler to allow for
movement of sprinkler without straining wire
connections. One common wire and one station
wire are required for each sprinkler. See Wire
Sizing Chart, Table 1 for proper application.
2. Attach control wires to solenoid leads using an
approved waterproof splicing method.
All wires must be waterproofed to prevent short
circuit to ground and subsequent controller
damage.
Connecting Hydraulic Control Tubing
1. Route control tubing from controller to sprinkler
location(s).
Note: Leave an 18 inch service loop of tubing at
each sprinkler to facilitate movement of sprinkler and
service operations. Tubing runs in excess of 1,000
feet are not advisable due to delayed response time.
The controller for hydraulic valve-in-head systems
should never be located more than 25 feet below or
more than 70 feet higher than the valves. Although
there is no limit to the amount of hydraulic valve-in-
head sprinklers controlled by one control station,
practical experience suggests the maximum number
of heads normally used is five.
2. Flush tubing thoroughly to remove all air and debris.
3. Remove tube retainer and poly cap from tubing
adapter at base of sprinkler.
4. Slide tube retainer over control tubing and attach tubing to adapter. Slide tube retainer over adapter area to
secure tubing.

System Start-Up

The following is a recommended procedure that will protect system components during system start-up. The
procedure is based on a velocity fill rate of less than 2 feet per second. See Table 2 below.
1. Use jockey pump only to fill system at velocity fill rate of less than 2 feet per second.
TO PREVENT PERSONAL INJURY, DO NOT STAND DIRECTLY OVER ANY
COMMERCIAL OR LARGE TURF HEAD DURING FILL OR WHEN ACTIVATING
MANUALLY AT THE HEAD.
2. Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from system lines
during filling process. Do not compress air and then relieve - bleed air while filling system.
3. After water has filled all lines and all air is removed, remove quick coupler keys.
Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer
effect that could damage sprinklers.
Table 2
Pipe Size
Inches
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
All manuals and user guides at all-guides.com
CAUTION
WARNING
CAUTION
Gallons Per
Velocity - Feet
Minute
Per Second
2
1.60
3
1.92
5
1.50
10
1.86
10
1.41
20
1.80
30
1.84
Table 1 - Wire Sizing Chart
Maximum Allowable Length in Feet From Controller to VIH Sprinklers.
VOLTAGE
WIRE SIZE
AT
CONTROLLER CONTROL COMMON
110 VAC
14
110 VAC
14
110 VAC
14
110 VAC
12
110 VAC
12
110 VAC
12
110 VAC
10
115 VAC
14
115 VAC
14
115 VAC
14
115 VAC
12
115 VAC
12
115 VAC
12
115 VAC
10
Chart based on the following: Transformer - 115 VAC - 124 VAC, 45 VA
Coil Assy.
Holding
In Rush
Pipe Size
Gallons Per
Inches
3
4
6
8
10
12
3
NUMBER OF VALVES
1
2
3
14
2348
1012
549
12
2890
1239
673
10
3378
1448
786
12
3759
1604
873
10
4591
1973
1071
8
5411
2328
1263
10
5945
2555
1387
14
2765
1309
846
12
3393
1608
1039
10
3962
1877
1213
12
4394
2082
1346
10
5397
2557
1652 1071
8
6364
3018
1949 1263
10
6986
3311
2140 1387
- 24 VAC, 60 Hz
- .21 Amps
- .42 Amps
Velocity - Feet
Minute
Per Second
45
1.86
75
1.87
150
1.73
250
1.70
450
1.97
500
1.55
4
353
433
505
561
688
812
892
549
673
783
872