Page 1
50M/100M/200M QUAD PHOTOELECTRIC BEAM SENSOR TA TAI 4PH-50TA / 4PH100TA / 4PH-200TA INSTRUCTION MANUAL 4PH-50TAI / 4PH100TAI / 4PH-200TAI Thanks for purchasing product. Read this instruction manual before using the product to make sure that you u e it correctly.
Page 2
NAMES OF FUNCTION SETTING SECTION Monitor - Alarm LED Monitor + SYNC Single (LED) 1.Weak Signal (LED) Beam Channel Switch Transmitter Power Switch Wiring Wiring 2. Master / Slave Switch Terminals Beam Channel Switch Terminals 2. Master / Slave Switch Response Time Adjustment 1.
Page 3
WIRING DIAGRAM CH_B CH_A CH_A CH_B Master Master CH_A CH_B Slave-1 Slave-1 CH_A CH_B Slave-2 Slave-2 CH_A CH_B Slave-3 Slave-3 Control Panel Receiver Transmitter Transmitter Receiver T/T Sync Signal Power Alarm Signal INSTALLATION METHOD: 4PH-XXXTA 4-6 Refer to ″8. ALIGNMENT AND OPERATION ADJUSTMENT″...
Page 4
BEAM CHANNEL CHANGEOVER FUNCTION & MASTER/SLAVE SWITCH: 5-1 When the existing range is shorter than product spec, then it only needs lower power for operation, please refer to Fig 5-1 for the setting. TRANSMITTER POWER SWITCH (TRANSMITTER) TRANSMITTER SYNC SIGNAL(LED) POWER SWITCH Model 4PH-50TAI 4PH-100TAI 4PH-200TAI...
Page 5
FOUR TO FOUR When doing FOUR TO FOUR installation, refer to Fig 5-3, firstly, setting " Master " in position, the second third four units setting with Slave-1, Slave2 and Slave-3 sequentially. CH_A CH_B CH_B CH_A (Master) (Slave-1) (Drawing 4) (Slave-2) (Slave-3) TRANSMITTER...
Page 6
RESPONSE TIME ADJUSTMENT: ● The beam interruption time adjustment is on Receiver Unit only. Speeds shown below are the maximum detectable speeds for each setting. Response time adjustment volume (ms) 50ms 100ms 300ms 500ms ( Receiver ) Running at full speed Running at slow speed Walking normally Walking slowly ※NOTE:In order to get the optimum setting for response time adjustment, operation testing is absolutely...
Page 7
1. Channel (A-B) setting should be identical on both TX and RX. Operation 2. Wrong Channel setting. 2. Master Slave 1, 2, 3 setting on TX and RX should be identical. SPECIFICATIONS: Model No. Model No. 4PH-50TA 4PH-100TA 4PH-200TA 4PH-50TA 4PH-100TA 4PH-200TA Items...
Page 8
2. Specifications and design are subjected to change without prior notice. 3. No take apart the product improperly, which possibly cause the damage. No.4-46, Fengren Rd., Renwu Dist., Kaohsiung City 81459, Taiwan (R.OC) Web Site : http : // www.sengate.com E-mail : service @ sengate.com TEL : +886-7-3721111~6...