1
Rotonivo

Function

2
A brushless synchronous motor drives a rotating measuring
vane.
When the material level reaches the measuring vane, it is
handicapped in its rotation. The motor is freely suspended
within the housing. The caused reaction torque is used to
3
operate a micro switch giving a signal output and to stop the
motor (figure 2).
When the paddle becomes free again due to falling material
level, a spring draws the motor back into his operating position,
the micro switch returns to his initial position and the motor is
switched on. The output signal is switched back (figure 1).
4
Signal output delay:
The version "universal voltage" and "PNP" has an integrated
adjustable delay for the signal output.
5
6
7
8
Electronics
9
Supply
24V or 48V or
AC version
115V or 230V AC
DC version
24VDC
10
DC version
24VDC PNP
Universal
24VDC /22..230V AC
voltage
Micro switch, Relais for universal voltage
(1)
Switchable signal output (Fail safe high /low)
(2)
11
12
page G
4
Level limit switch
®
Series RN 4000
Technical information / Instruction manual
Microswitch for
Switching
signal output
part
Figure 1
Signal output
-
-
-
-
Option fail safe alarm
With the fail safe alarm it is possible to recognize a fault of the
unit in time and to initiate an alarm relay. The following faults are
observed:
Motor
Gear
Electronic for motor power supply
Supply voltage failure
Defect of the connecting wires
Umschaltbare Sicherheitschaltung FSH/FSL:
Bei Ausführung "Allspannung", "PNP" und optional bei "AC" ist
eine umschaltbare Sicherheitsschaltung FSH/FSL integriert.
Microswitch for
motorstop
FSH/
Adjust.
Fail safe
(2)
delay
alarm
FSL
option
-
-
-
-
-
-
option
gi010114
Figure 2
RN 4000