Technical information / Instruction manual
Power supply:
• AC version:
24V or 48V or 115V or 230V 50/60Hz max. 4VA
All voltages ±10%
(1)
Supply voltage as selected.
External fuse: max 10A, fast or slow, HBC, 250V
• DC version:
24V DC ±15%
max. 2.5W
(1)
External fuse: not required
• Universal voltage:
24V DC ±15%
max.4W
(1)
22 .. 230V 50/60Hz ±10%
(1)
External fuse: not required
including ±10% of EN 61010
(1)
Signal and alarm output:
Micro switch or relay, SPDT contact
max. 250V AC, 2A, 500VA (cos
max. 300V DC, 2A, 60W
External fuse: max 10A, fast or slow, HBC, 250V
Power supply:
24V DC ±15%
(1)
including ±10% of EN 61010
(1)
Input current: max. 0.6A
Signal output:
Load max.0.4A
Output voltage equal to input voltage, drop <2,5V
Open collector
Protected against short circuit and overload
max.10VA
j
= 1)
gi010114
Signal
Alarm
output
output
(2)
With option Fail safe
(2)
alarm (rotation control)
Contact open when de-energised
+
-
Load PE*
Power
supply
max.1.5mm²
(AWG16)
L
N
PE*
+
-
Power supply
max.1.5mm²
(AWG16)