Thermo Scientific ULT-10140-9-D Installation And Operation Manual
Thermo Scientific ULT-10140-9-D Installation And Operation Manual

Thermo Scientific ULT-10140-9-D Installation And Operation Manual

Cryogenic storage freezers

Advertisement

Cryogenic Storage
Freezers
Installation and Operation
325440H01 Rev. A December 2013
Visit us online to register your warranty
www.thermoscientific.com/labwarranty

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific ULT-10140-9-D

  • Page 1 Cryogenic Storage Freezers Installation and Operation 325440H01 Rev. A December 2013 Visit us online to register your warranty www.thermoscientific.com/labwarranty...
  • Page 2 IMPORTANT Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the unit, injury to operating personnel, and poor equipment performance. CAUTION All internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for informational purposes only.
  • Page 3 Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice.
  • Page 4: Table Of Contents

    Table of Contents Table of Contents Cryogenic Models..............1 Safety Precautions..............2 General Recommendations ............4 Temperature Monitoring ............4 Recommended Use ..............4 Unpacking ................4 Operating Standards ..............5 Electrical Specifications ............5 Installation ................6 Location...................6 Wiring ..................6 Leveling ...................7 Operation .................8 Control Panel Features.............8 Initial Loading ...............10 Start Up .................11 Frame Heater Switch..............14 Backup System (Optional) .............15...
  • Page 5: Cryogenic Models

    Cryogenic Models 1 Cryogenic Models The following cryogenic models are described in this manual: Model Number Suffix ULT-10140-9-D ULT-10140-9-M ULT-10140-9-V ULT-7150-9-D ULT-7150-9-M ULT-7150-9-V Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 6: Safety Precautions

    Before installing, using or maintaining this product, please be sure to read this manual and product warning labels carefully. Failure to follow these instructions may cause this product to malfunction, which could result in injury or damage. 2 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 7 Never connect the unit to overloaded power sources. WARNING: Disconnect the unit from all power sources before cleaning, troubleshooting, or performing other maintenance on the product or its controls. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 8: General Recommendations

    CAUTION! Do not discard the sublids from chest-style units. The sublids are necessary to maintain correct temperature, moisture control, and economy of operation. 4 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 9: Operating Standards

    Phase 10140D 208/230V 60Hz/1 23.0/30A Ø 10140M 380V 50Hz/3 11.0/15A Ø 10140V 230V 50Hz/1 23.0/30A Ø 7150D 208/230V 60Hz/1 23.0/30A Ø 7150M 380V 50Hz/3 11.0/15A Ø 7150V 230V 50Hz/1 23.0/30A Ø Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 10: Installation

    National Electrical Code and local codes. Do not connect the unit to overloaded power lines. CAUTION Do not position the unit in a way that impedes access to the disconnecting device or circuit breaker in the back of the unit. 6 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 11: Leveling

    The unit must be level both front to back and side to side. To level chest models, leave the casters in place and shim the low wheel(s) with strips of sheet metal cut at least 1/2 in. wider than the caster. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 12: Operation

    Figure 1. Control Panel with Optional Backup System Before the initial start up, take some time to become familiar with the controls on your freezer. Figure 1 illustrates the Thermo Scientific Cryogenic Freezer control panel. Note: Figure 1 shows all possible functions. These functions vary depending on the options.
  • Page 13 19. Voltage Boost Indicator. This indicator lights when incoming voltage is low and the Voltage Safeguard has been activated. Press this pad to display the current line voltage in the digital display window. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 14: Initial Loading

    Allow the freezer to operate at the desired temperature for a minimum of 12 hours before loading. CAUTION! Failure to follow these procedures or overloading the unit may cause undue stress on the compressor or jeopardize user product safety. 10 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 15: Start Up

    4. Release both pads when the digital temperature display window shows the correct setpoint value. Note: If no keys are pressed within ten seconds, the temperature display reverts to the cabinet temperature. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 16 IMPORTANT NOTE: You must turn the three-position key switch to the ALARM ON/SETPOINT SECURITY position to activate the alarm and place it in security operation. Do not perform this action until the cabinet temperature drops below the warm alarm setpoint. 12 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 17 Temperature pad in conjunction with either the Warm Alarm Setpoint pad or the Cold Alarm Setpoint pad. Note: Once the Alarm Reset button is depressed, the excursion temperature value is reset to the current cabinet temperature. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 18: Frame Heater Switch

    Heating the frame has no effect on interior cabinet temperature. You can turn on the switch whenever there is condensation near the lid. 14 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 19: Backup System (Optional)

    Use this panel to set the backup initiation temperature: Digital Temperature Temperature Control Display Setpoint Screw TEMPERATURE °C POWER PUSH TO SET SETPOINT ADJUST Power Temperature Control Switch Set Button Figure 2. Control Panel for Optional Built-In Backup System Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 20 LN supply. Straighten the coiled tubing and connect one end to the labeled connection on the freezer and the other end to the supply bottle or building supply fitting. 16 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 21 The built-in battery charger recharges the battery to full charge when power is restored to the system. Note: Since rechargeable batteries degrade over time, the battery should be replaced after approximately one or two years. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 22 -150×C -140×C -130×C -120×C Liquid LN Chest Freezers Empty 11.3 10.0 7 ft 3 1/2 Full Full Empty 15.2 13.5 11.9 10.3 10 ft 3 1/2 Full 12.0 10.4 Full 18 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 23: Maintenance And Troubleshooting

    Make sure that the cabinet is level (refer to Section 5.3 on page 7 for leveling information). Keep the lid gasket clean and frost free by wiping gently with a soft cloth or soft brush. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 24: Defrosting The Freezer

    3. Remove the battery and put the new battery in place. Note: You may have to cut a strip of silicone rubber in order to remove the battery. 4. Connect the battery terminals and replace the front grill. 20 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 25: Troubleshooting Procedures

    Alarm battery is low on charge . indicator is on. Voltage Boost indicator Low incoming line voltage to the freezer.. is on. No display, no fans No power to the unit. running. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 26: Chart Recorders

    9 Volt Battery Chart Buttons Imprinting Stylus Reference Mark Hub-Nut and Chart Retaining Wire Figure 4. Chart Recorder CHANGE CHART Figure 5. Chart Buttons 22 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 27: Power Supply

    2. Measure cabinet center temperature with a calibrated temperature monitor. 3. Compare the recorder temperature to the measured cabinet temperature. If necessary, adjust recorder by pressing the left (#1 in Figure 6) and right (#2) chart buttons. Thermo Scientific Cryopgenic Storage Freezers Installation and Operation Manual...
  • Page 28 4. When the green LED blinks 3 times to confirm the resetting, press the #3 button. The pin arm should then return to indicate the current temperature. Repeat Steps 1-3 if necessary. 24 Installation and Operation Manual Thermo Scientific Cryogenic Storage Freezers...
  • Page 29: Warranty

    Your local Thermo Scientific Sales Office is ready to help with comprehensive site preparation information before your equipment arrives. Printed instruction manuals carefully detail equipment installation, operation, and preventive maintenance.
  • Page 30 Your local Thermo Scientific Sales Office is ready to help with comprehensive site preparation information before your equipment arrives. Printed instruction manuals carefully detail equipment installation, operation, and preventive maintenance.
  • Page 31 Important For your future reference and when contacting the factory, please have the following information readily available: Model Number: Serial Number: Date Purchased: The above information can be found on the dataplate attached to the equipment. If available, please provide the date purchased, the source of purchase (manufacturer or specific agent/rep organization), and purchase order number.
  • Page 32 Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 United States www.thermofisher.com...