9. If the main circuit board is replaced when
troubleshooting and you are not sure if the new main
circuit board will be kept in the relevant product, it is
possible to temporarily program the main circuit
board in a so-called Service Mode. Refer to
Programming a new main circuit board on page 10 .

5.11 The battery system

WARNING: Use only original batteries
recommended by the manufacturer. Product
safety cannot be guaranteed with other
batteries. Do not use non-rechargeable
batteries.
The battery is considered to be fully charged when the
battery reaches 80% of the total capacity. To charge the
battery to 100% would take too long since the charging
current is low. The most rational way of using Li-ion
batteries is therefore to stop charging at 80%. The
maximum utilised capacity is thus 80% of the battery's
total capacity.
The battery is maintenance-free, but has a limited life
span. The battery is expected to last for 3000 - 4000
charging cycles. The normal charging current is 1 or 1.3
A.
5.11.1 To replace the battery
1. Remove the lower chassis. Refer to
install the lower chassis on page 14 .
2. Disconnect the battery cable from the main circuit
board.
1595 - 001 - 01.02.2021
3. Remove the screw for the bracket.
4. Remove the battery.
To remove and
5. Install in the opposite sequence.
Note: When replacing the battery, the charging cycle
counter should be reset. This is done in Autocheck.
5.11.2 To replace the charging plates on the
product
When the product's battery does not recharge this may
be due to worn or damaged charging plates.
The charging plates are included in the main circuit
board. Refer to
page 16 .
To replace the main circuit board on
Repair instructions - 17