Further information

Caring for the load bars
Cable damage is the most common reason for load cell failure. To avoid damage, secure and protect cables.
Do not weld the chute/crush or brackets with the load cells in place.
Do not wash using a high pressure hose.
Regularly clean out manure and stones from under the chute/crush and around the cells.
Do not leave submerged in water for long periods.
Service and warranty information
For service and warranty information, see www.tru-test.com.

Specifications

Capacity
4 x 2,500 lbs (1,136 kg) load cells with a total capacity of 10,000 lbs (4,500 kg)
Accuracy
1% or 4 lbs (2 kg), whichever is greater
Sensitivity
0.266 mV/V @ 2,500 lbs
Cable length
26 ft. (8 m)
Environmental
Operating temperature +15 to +105 °F (-10 to +40°C)
Storage temperature -5 to +120 °F (-20 to +50 °C)