External Unit: Overview Of Connections - Viessmann VITOCAL 222-S Installation And Service Instructions Manual

Table of Contents

Advertisement

Electrical connection
Plug
Component
F101
Fuse 1.0 A (slow L)
P202
BUS connection (12 V to external unit for type AWT/AWT-AC 221.A10/A13, 221.B10 to
B16)
P203
BUS connection (43 V to external unit for type AWT/AWT-AC 221.A04 to A07)
Note
Only one BUS connection should be connected.
Do not interchange the BUS connection wires
between the internal and external units.
Route the BUS connecting cable in the 230 V~ volt-
age area.

External unit: Overview of connections

Opening external unit wiring chamber
Type AWT/AWT-AC
221.A04
A
Fig. 31
Wiring chamber:
A
BUS connection to the internal unit
Note
Do not interchange the BUS connection wires
between the internal and external units.
Compressor power supply
(cont.)
221.A05/A07
A
Fig. 32
Installation sequence
221.A10/A13/B10/B13/B16
A
Fig. 33
39