LEDS

The LED lamp used in this appliance cannot be replaced by the end user. If there is a fault with the LED lamp, please contact
.
the Service Department

CLEANING

SAFETY PRECAUTION
Before cleaning your rangehood or performing any maintenance, please ensure that the rangehood is turned off at the
power point.
Do not use abrasive cleaners to clean the rangehood. The use of warm soapy water and a cloth are recommended.
Ensure that the rangehood is cleaned regularly, as a build-up of grease and fat may occur otherwise.
The filters on the rangehood must be cleaned regularly to maintain efficiency, and prevent grease build up. It is
recommended that this is undertaken every 4 – 6 weeks, depending on frequency of use.
The filters can be cleaned with warm soapy water or a cloth.
Cleaning of the rangehood must be performed as described above; otherwise there is a possibility of a fire hazard due to
grease and fat build up.
If the rangehood is fitted with charcoal filters (for re-circulating) it is recommended that the filters be changed every 3 – 4
months. Filter replacement will ensure correct function of the rangehood, and ensure that the air being re-circulated back
into the room is clean.

TROUBLESHOOTING

Fault
Fan switch turned off
Light on, but motor
Fan switch failed
does not work
Motor failed
Light does not
House fuses blown
work, motor does
Power cord loose or disconnected
not work
One way valve and the air ventilation entrance
are not tightly sealed
Oil leakage
Leakage from the connection of U-shaped
section and cover
Lights not working
Broken/Faulty globes
The distance between the range hood and the
Insufficient suction
gas top is too far
The Range hood
The fixing screw not tight enough
inclines
NOTE: Any electrical repairs to this appliance must conform to your local, state and federal laws. Please contact the service
centre if in any doubt before undertaking any of the above. Always disconnect the appliance from the power source when
opening the appliance.
8
Possible Cause
EASY DECISION
Solution
Select a fan switch position.
Contact Service Department.
Contact Service Department.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Take down the one way valve and seal with
sealant.
Take U-shaped section down and seal.
Contact Service Department.
Refit the range hood to the correct distance.
Tighten the hanging screw and make it
horizontal.