2. INSTALLATION

C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
After unpacking the 3192 H4TU-C, inspect it for
damage. If damage has occurred, file a claim with the
carrier, then contact ADTRAN Customer Service.
Refer to the
Warranty and Customer Service
further information. If possible, keep the original
shipping container for returning the 3192 H4TU-C for
repair or for verification of shipping damage.
CAUTION
Electronic modules can be damaged by ESD.
When handling modules, wear an antistatic
discharge wrist strap to prevent damage to
electronic components. Place modules in
antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.
Front Panel
Label
DSL 1
H TUC
DSL 2
1223404L2
DSX/DS1
DSL 1
DSL 2
ALM
DSX
DSX EQ
/DS1
ALM
TX
ESF/SF
ESF
/SF
RX
B8ZS
/AMI
LBK
TX
RX
B8ZS/AMI
DSX MON
LBK
R
S
2
3
2
61223404L2-5A
section for

Table 3. Front Panel LED Indicators

Condition Description
DSL Loop 1 and Loop 2 sync, no errors detected, and signal margin ≥ 3 dB.
Green
Red
No DSL Loop 1/ Loop 2 sync, errors detected, or signal margin < 3 dB.
Green
DSX-1 signal is present, and no errors being detected.
Red
In framed mode, denotes loss of framing or loss of sync at the DSX/DS1
input; in unframed mode, denotes loss of signal at DSX/DS1 input.
Off
No active alarm present.
Red
Loss of DSX-1 signal to the unit.
Yellow
Loss of DS1 signal to the remote.
Off
Unit is provisioned for unframed data.
Yellow
Unit is provisioned for ESF data.
Green
Unit is provisioned for SF data.
Yellow
Unit is provisioned for B8ZS line code.
Green
Unit is provisioned for AMI line code.
Off
Unit is not in loopback.
Yellow
Unit is in loopback (network and/or customer).
Issue 1, December 2003
Instructions for Installing the Module
To install the 3192 H4TU-C, perform the following
steps:
1. If present, remove the Access Module Blank from
the appropriate access module slot of the HDSL4
chassis.
2. Hold the 3192 H4TU-C by the front panel while
supporting the bottom edge of the module.
3. Align the module edges to fit in the lower and
upper guide grooves for the access module slot.
4. Slide the module into the access module slot.
Simultaneous thumb pressure at the top and at the
bottom of the module will ensure that the module is
firmly positioned against the backplane of the
chassis.
When the 3192 H4TU-C first powers up, it runs the
power up self-tests. Once the power up self-test is
complete, the status LEDs will reflect the true state of
the hardware.
Front Panel LEDs
LED indicators mounted on the front panel of the unit
provide the status of the HDSL circuit. See
a listing of the front panel LEDs and their indications.
Table 3
for
3

Advertisement