BALANCE INSTRUCTION MANUAL
SERIES 4B/NA(N)
File: 2012-04 4BPA-048 B-50_4 GB

Advertisement

Table of Contents
loading

Summary of Contents for Axis 4B/NA Series

  • Page 1 BALANCE INSTRUCTION MANUAL SERIES 4B/NA(N) File: 2012-04 4BPA-048 B-50_4 GB...
  • Page 2: Table Of Contents

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Table of contents: General description ................................3 Completation ..................................4 Technical data ..................................4 Safety principles ..................................5 Principles of used balance treatment ............................. 5 Balance keys and indicators ..............................6 Balance preparation to work ..............................7 Balance start ..................................
  • Page 3: General Description

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 1. General description Drive-through balances from 4B/NA series in basic version from lacquered steel, with SE-01/A/18 meter, are designed for operation in light environmental conditions. Manual describes standard balance version. In case of special meter use, e.g.
  • Page 4: Completation

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 2. Completation Basic set includes: 1. Bearing surface, 2 drive-throughs and balance meter, connected permanently with cable 2. 4 locks 3. RS232C connector (only 4B/NAN balances) 4. Instruction manual 5. Warranty 3. Technical data Balance type 4B300 4B600 4B1000 4B1500...
  • Page 5: Safety Principles

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 4. Safety principles It is necessary to become familiar with safety principles shown below, which are necessary to avoid electric shock and damage of balance or connected devices. • Repairs and necessary adjustments must be performed by qualified personnel only.
  • Page 6: Balance Keys And Indicators

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 6. Balance keys and indicators - ON/OFF switch (standby), → ← - tare setting (entering of mass subtracted from weighed mass), - gross weight indication, → ← - zeroing, MENU - special functions menu, - result print, - weight indication resolution increasing, indicator →...
  • Page 7: Balance Preparation To Work

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 7. Balance preparation to work 1. Unpack balance, removing protective foils. 2. Place balance on flat, horizontal foundation, in place not subjected to mechanical vibrations and strong air movements. Take care if the scale stays on all four legs. 3.
  • Page 8: Balance Start

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 8. Balance start Connecting of supply plug to socket of ~230V/50Hz installation with unloaded balance will cause the following sequence of actions: Display test Tests of basic electronic subassemblies, ended with messages: C1, C-2, ... C-6. Displaying of software version. Ready for operation.
  • Page 9: Operation Principles

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 9. Operation principles 1. Before each measurement the balance should be properly zeroed, which is signalled by “→0←” indicator. If the zero indication is not shown when the →0← balance is unloaded, or "----" is displayed, press the " "...
  • Page 10: Balance Test

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Balance test During balance operation, in order to confirm its efficiency, it is recommended to check the weighing precision by putting and object of exactly known weight before and after series of measurements. For testing of verified balances use weight standard, having valid standardization certificates.
  • Page 11 In special features scale can be equipped in second RS232 interface for additional functions, ex. continuous transmitting of indications to second display. Computer must have a special program for cooperation with data from a scale. Programs offer is available on www.axis.pl/en internet site. Detailed protocol description LonG protocol...
  • Page 12 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Asking for scale presence in system (testing scale connection with computer): Computer→Scale: S J CR LF (53h 4Ah 0Dh 0Ah), Scale→Computer: M J CR LF (4Dh 4Ah 0Dh 0Ah), Displaying a sign on scale display (text message from computer): Computer→Scale: S N n n X X X X X X CR LF (53h 4Eh 0Dh 0Ah), nn-displaying time in seconds;...
  • Page 13 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Connecting cable WK-1 (scale – computer / 9-pin interface): Protocol ELTRON description Communication parameters: 8bits, 1stop, no parity, 9600bps, After use key scale send: Scale→Label printer : EPL-2 language instruction to initialize print of label: - control instruction FR"0001"...
  • Page 14: Basic Function

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Basic function To make clear how to manage with each function, in further part of instruction descriptions are replaced with pictures. - put a load on the pan - remove the load from the pan 2.30 press the key when indication is displayed - forced change - automatic change...
  • Page 15: Weighing With Tare

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 13.2 Weighing with tare The scale is equipped with tare equal 2.30 to its range. Joint value tare and mass net can not 0.00 cross a maximum of scale. To display gross weight press B/G key. 40.01 Note: Press B/G key to return to net weight indication.
  • Page 16: Special Functions Describtion

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Special functions describtion List of available functions: menu customization function (ACtIV), removal of all function from menu (dEFAUL). autozeroing function (AutoZE), pieces counting function (PCS), function for setting serial port working (PrInt) function for setting serial port (Port) entering tare function (tArE) recipe weighing function (rECIPE), weighing large animals function (LOC)
  • Page 17: Menu Customization Function (Activ And Defaul)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.1 Menu customization function (ACtIV and dEFAUL) Among available user functions it is 0.00 possible to select these, which should be displayed after pressing MENU key. It allows avoiding displaying whole list of available functions, which makes ACtIV operation time longer.
  • Page 18: Autozeroing Function (Autoze)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.2 Autozeroing function (AutoZE) When F..-Aut function is activated, 0.01 the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by → ← pressing key. AutoZE To leave the function press MENU →...
  • Page 19: Pieces Counting (Pcs)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.3 Pieces counting (PCS) This function enables to count identical pieces, e.g. turnbuckles or 0.00 buttons. A measurement is performed in two phases: - first phase - single piece weight calculation on the basis of defined 23.40 pieces amount (5, 10, 20, 50, 100, 200 or 500 pieces), - second phase –...
  • Page 20: Printer Cooperation Settings (Print)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.4 Printer cooperation settings (PrInt) Activate the function for automatic 0.00 serial port working mode (cooperation with a printer. After activation the scale prints a header. Weighing result with PrInt a successive measurement number is printed automatically after result stabilisation (without using key).
  • Page 21: Serial Port Parameters Setting (Port)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.5 Serial port parameters setting (Port) 0.00 The function enables to set the following transmission parameters (standard parameters underlined: Port - transmission protocol (Prot): LonG - printer, ELtron – label printer, - transmission speed (bAud: 1200, Port-0 4800, 9600, ...), - the number of bits in a byte (bit: 7, 8), - parity control (PArItY: 0, 1;...
  • Page 22: Constant Tare (Tare)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.6 Constant tare (tArE) This function enables to measure gross weight of a sample placed in a container of a known weigh value (stored in the memory) and to display calculated net weight of the sample. Tare →...
  • Page 23 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Weighing with constant tare: When tAr function is activated, press -1.70 → ← key to zero the indication and to recall tare value from the memory. Tare value is displayed with ”-” sign. 10.00 enables instant switching between net and gross weight.
  • Page 24: Average Calculation Function (Averag)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.7 Average calculation function (AVErAG) The function allows for calculating average value of performed measurement series. During series of measurements successive results are registered automatically when scale indication is stabilised. Press MENU key and select AUErAG 0.00 →...
  • Page 25: Recipe Weighing Function (Recipe)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.8 Recipe weighing function (RECIPE) 0.00 This function allows for separate MENU weighing of several ingredients in one container with a possibility of control total weight of all weighed rECIPE components. The function has the following options: rECI- 0 - rECI-0 –...
  • Page 26: Percentage Weighing Function (Perc)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.9 Percentage weighing function (PErC) This function allows displaying weighing result in percents. A measurement is performed in two phases: 0.00 first phase – weighing reference sample (100%), 100% second phase – measuring specific sample as a percentage 1.70 of the reference sample.
  • Page 27: Anti-Disturbance Filter Function (Filter)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.10 Anti-disturbance filter function (FILtEr) This function allows using digital filter 0.00 with selected intensivity during weighing. Filter reduces the influence of mechanical vibrations (air blasts, FILtEr base vibrations) on measurement result. Press MENU key and select FILtEr →...
  • Page 28: Function For Maximum Value Indication (Up)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.11 Function for maximum value indication (UP) This function allows holding on display maximum value shown by the scale in a while. Before measurement scale should be tared. 0.00 After using MENU key and selecting UP function the highest mass result will be hold on display.
  • Page 29: Force Measuring Function (Newto)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.12 Force measuring function (nEWto) Function activation causes displaying result in force units (N). Press MENU key. nEWto → ← Using key choose NEWto function, and then NEW-1. Note: 1N≈0,1019kg nEW -0 nEW -1 0.000...
  • Page 30: Function For Weighing Large Animals (Loc)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.13 Function for weighing large animals (LOC) The function allows weighing animal moving on the scale. Press MENU key. 0.00 MENU When LOC function is displayed press → ← key. The following options appear on display successively: L OC - LOC-0 –...
  • Page 31: Checkweighing Function (Thr)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.14 Checkweighing function (thr) This function allows comparing weighing result with two programmed reference values: lower and upper threshold. Comparison result is signalled with indicators (MIN, OK, MAX) and sound signal generated when threshold values are exceeded. If comparison result is: - smaller than lower threshold –...
  • Page 32 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Relays connection diagram: Imax < 25mA Relays output is the open collector transoptor output with load capacity 25mA / 24V. Transmitter inputs must be protected with diodes, e.g. 1N4148. It is advised to use MS3K/P electronic board (sold separately), consisting of RM96P transmitters, with DC24V input voltage and AC250V, 3A output.
  • Page 33 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Operation sequence: Press MENU key and choose thr 0.00 → ← pressing key. The following options are displayed successively: - thr-0 – deactivate the function, - thr-1 – activate the function, - thr-P – check last threshold values (press key several times), thr -0...
  • Page 34: Total Weight Function (Total)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.15 Total weight function (totAL) The function allows calculating total weight for series of measurements, which can be grater than scale capacity. It allows calculating total weight as well as average value. Press MENU key. → ← 0.00 When totAL is displayed press key.
  • Page 35 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ To leave the function with clearing total register, select total function from menu and choose tot-0 option. When It will cause the scale prints the communicate informing about clearing registers The form of receipt after each measurement: Date: Time.
  • Page 36: Function For Setting Date And Time (Date)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.16 Function for setting date and time (dAtE) The function allows setting current 0.00 date and time of scale internal clock and mode of its use. The function has the following dAtE options: - dAt-0 – deactivate date and time during printout of current weighing dAt- 0 result,...
  • Page 37: Function For Selecting Label Number (Label)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.17 Function for selecting label number (LAbEL) The function appears in scales with ELTRON data transmission protocol. This protocol allows printing scale indication and optionally date and time on label printer, as variable texts. Other data, e.g. company address, product name, its bar code can appear on label as constant fields.
  • Page 38: External Calibration (Calib)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.18 External calibration (CALIb) Note: This function is enabled in non legalized scales only. Calibration of sensitivity should be make when aaccuracy of scale is not satisfactory. Could use standard mass equal of maximum range of scale (Max). Operation sequence: Press MENU key to call functions 0.00...
  • Page 39: Setting Time Of Stabilization Function (Stb)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.19 Setting time of stabilization function (Stb) The function allows changing stabilisation time of scale indication and connected with it the time of waiting for starting result printout on a printer connected to the scale. Press MENU key. 0.00 →...
  • Page 40: Entering Reference Zero Function (Zero)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.20 Entering reference zero function (Zero) Note: This function is enabled in non legalized scales only. ZER function allows entering new value of reference zero (value referred to empty pan) without need of contacting with authorised service centre. Err-b Press MENU key while Err-b is displayed.
  • Page 41: Automatic Switching Off The Scale Function (Autoof)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.21 Automatic switching off the scale function (AutoOF) The function is helpful in scales supplied from accumulator. The function causes scale to switch off automatically after c.a. 10 minutes of not using it. Switching function on causes last entered zero and tare values are remembered in scale memory.
  • Page 42: Density Determining Function (Densit)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.22 Density determining function (dEnSIt) The function allows determining 0.00 solid density basing on its weight in the air and in liquid of known density using the formula below: dEnSIt g=  * g liquid dEn -1 where: m -weight in the air - weight in liquid...
  • Page 43 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ If a printer is connected to the scale, printout of solid density measurement results will be performed in the following form: Date: ... Time..MEASUREMENT No. = WEIGHT in air WEIGHT in liquid HANGER WEIGHT LOAD DENSITY g/cm LIQUID DENSITY g/cm...
  • Page 44: Statistical Calculations Function (Stat)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14.23 Statistical calculations function (StAt) Attention: Function is available on demand and it replaces other special functions. This function evaluates from series of measurements (max 500) statistical parameters of weighting process. Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize.
  • Page 45 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ This will cause printout of calculated statistics Data: Hour..SAMPLES and histogram : TOTAL MASS AVER MASS MIN MASS LSL - allowable lower value, MAX MASS = MAX – MIN USL - allowable upper value, SREL A, B, C, ..
  • Page 46: Maintenance And Small Repairs

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 15. Maintenance and small repairs 1. Keep the balance clean. 2. Take care, for during the operation some impurities may enter under balance base and into sensors vicinity. In case of impurities finding remove them. 3. In case of improper operation due to short power failure, switch off the balance by unplugging the power cable from the socket, and plug it again after a few seconds.
  • Page 47: Declaration Of Conformity

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Declaration of Conformity AXIS Spółka z o.o. 80-125 Gdańsk, ul.Kartuska 375B declare with full responsibility, that the balance: 4B300NA, 4B600NA, 4B1000NA, 4B1500NA i 4B2000NA, 4B300NAN, 4B600NAN, 4B1000NAN, 4B1500NAN i 4B2000NAN oraz marked with CE mark are consistent with: 1.
  • Page 48 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Appendix A Information’s concerning double-range scale (options) 1. General description Double-range scale’s have capability of work with greatest accuracy in bottom measuring range part. Weighing of smallest mass is more precise. This type of scale’s have two measurement range: - 50 % of maximum load (mostly), –...