GENERAL USER INFORMATION
5.
Leakage currents due to ringing voltage - Earthing installation
instructions: '1. A supplementary equipment earthing conductor is
to be installed between the product or system and earth, that is, in
addition to the equipment earthing conductor in the power supply
cord.
2. The supplementary equipment earthing conductor may not be
smaller in size than the unearthed branch-circuit supply conductors.
The equipment earthing conductor is to be connected to the product
at the terminal provided, and connected to earth in a manner that ill
retain the earth connection when the power supply cord is
unplugged.
The connection to earth of the supplementary earthing conductor
shall be in compliance with the appropriate rules for terminating
bonding jumpers in Part K of Article 250 of the National Electrical
Code, ANSI/ NFPA 70 and Article 10 of Part 1 of the Canadian
Electrical Code, Part 1, C22.1. Termination of the supplementary
earthing conductor is permitted to be made to building steel, to a
metal electrical raceway system, or to any earthed item that is
permanently and reliably connected to the electrical service
equipment earthed.
3. Bare, covered, or insulated earthing conductors are acceptable.
A covered or insulated conductor must have a continuous outer
finish that is either green, or green with one or more yellow stripes.'
VI
© SAMSUNG Electronics Co., Ltd.