Alula RE617 Manual

Alula RE617 Manual

Connect+ encrypted heat alarm

Advertisement

Quick Links

RE617 Heat Alarm
device that alarms when it detects
temperatures above 135°F (57°C) or
temperature changes greater than 15°F
(8.3°C)/min and the temperature is
above 104ºF (40ºC).
Features
• UL539 and ULC-S530 listings
• Heat detection
Quick Start Guide
1. Remove the mounting plate.
2. Pull the battery tab.
3. Restore the mounting plate and
twist it fully onto the Heat Alarm.
Note: Enrollment is possible only
if the mounting plate is twisted
onto the Heat Alarm.
4. Enroll the Heat Alarm by placing the
panel into wireless enrollment mode
and then holding down the Heat's
test button until the Heat Alarm
beeps.
5. Remove the mounting plate and
refer to Sections 2 and 5 for
positioning and installation.
6. After mounting plate is installed
restore the Heat Alarm onto the
mounting plate and fully test the
Heat Alarm per Section 6.
Alternate Enrollment Methods
• Scan the Heat Alarm's bar code
using the Connect+ Installer app
OR
• Enter the 8-character serial
number on the interactive service
provider's web portal.
To replace the battery,
Heat Alarm from its mounting plate
and replace the batteries.
This manual should be read prior to use and retained for further information.
Use the panel installation guide to verify proper system setup.
RE617 Heat Alarm
Connect+
is a fire-protection
detach the
Attention
Encrypted
Pull Battery Tab
12 inches
minimum
Position Heat Alarm
Test Heat Alarm
I
12 inches
minimum

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE617 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alula RE617

  • Page 1 RE617 Heat Alarm Connect+ Encrypted ™ RE617 Heat Alarm is a fire-protection device that alarms when it detects temperatures above 135°F (57°C) or temperature changes greater than 15°F (8.3°C)/min and the temperature is above 104ºF (40ºC). Features • UL539 and ULC-S530 listings •...
  • Page 2: Normal Operation

    Indicator Summary Normal Operation Action Red LED Yellow LED Sounder Power Up Insert Battery 1 Flash 1 Flash Standby Sensing Fire Rapid Flashing Full Sound Fault Mode Action Red LED Yellow LED Sounder Low Battery 1 Flash every 48 sec 1 Beep Faulty Heat Sensor 2 Flashes every...
  • Page 3 (2) Outside of each separate dwelling unit Alarms should be located in a typical sleeping area within 6.4 m (21 ft) of any two story house. Note the spacings in door to a sleeping room, the distance “Protection Levels” which ensure the early measured along a path of travel detection of fire and that the warning will (3) On every level of a dwelling unit,...
  • Page 4: Fire Safety Advice

    Figure 2 premises having a residential type environment. • This is not a portable product. It must be Bedroom mounted following the instructions in this Kitchen Laundry instruction leaflet. Dining Room Room • Heat Alarms are not a substitute for insurance.
  • Page 5: Alarm Limitations

    3. Get out as fast as you can. Do not stop 4. Taking care to avoid any electrical wiring for packing. Have a prearranged meeting in the ceiling, drill holes using a 5.0mm place outside for all family members. Check drill bit through the center of the marked everybody is there.
  • Page 6: Power Supply Monitoring

    Figure 5b - How to Remove WARNING: DO NOT TEST WITH FLAME. This can set fire to the Alarm and damage PUSH UP CATCH & TWIST the house. We do not recommend testing ALARM ANTI-CLOCKWISE TO REMOVE with heat or flame as the results can be misleading unless special apparatus is used.
  • Page 7: Troubleshooting

    Wireless Verification Other than the maintenance and cleaning described in this leaflet, no other customer Heat alarm model RE617 has only been servicing of this product is required. evaluated at ETL with Alula Connect+ Repairs, when needed, must be performed Model#: RE6100.
  • Page 8: Specifications

    Changes or modifications not expressly approved by (1) L’appareil ne doit pas produire de brouillage, et Alula could void the user’s authority to operate this (2) L’utilisateur de l’appareil doit accepter tout equipment. brouillage radioélectrique subi, même si le FCC ID: U5X-RE314 brouillage est susceptible d’en compromettre le...