Download Print this page

LaserLinc Pivot Table Quick Start Manual page 4

Advertisement

'ESC'
Will force the PLC to reverse the direction of the fixture. This is not necessary for normal
operations. Care must be taken to not force the fixture into an over limit rotation.
'–'
Not functional
'+'
Not functional
'OK'
Not functional
Controls
HALT switch (located on the left and right side panels)
When pushed, the switch will lock and force the PLC into a halt mode. The fixture will coast
and stop rotation. The PLC displays "HALT". Turn the switch clockwise to release the halt
position.
Speed Control (located on the left side panel) – Left Control
Adjusts the speed of rotation from 0 (no rotation) to 50 (full speed)
1 = Min Speed: 80 seconds for 180 degrees of rotation
50 = Max Speed: 4 seconds for 180 degrees of rotation
Rotation Control (located on the left side panel) – Right Control
Adjusts the rotation from approximately +/- 2 degrees to +/- 90 degrees. The rotation varies
slightly based on the speed setting due to the decay of inertia during coasting just prior to a
reversal.
Misc
Encoder Output
Quadrature Encoder output
A/C Line Requirements
110VAC – 240VAC 50Hz – 60Hz universal input. 0.75A @ 120VAC; 0.40A @ 220VAC
Fuses
AC Line Fuse - 1A / 250VAC Fast Blo
24V DC Fuse - 2A / 250VAC Fast Blo
Page 4 of 4