Timeout Condition
The fixture has a built-in watchdog timer that will force a Halt condition if a timer expires before
seeing a limit sensor. During a timeout condition, the "Timeout" message will appear on the display
and halt the fixture. If this occurs, then there is most likely a problem with a limit sensor(s) or magnet
on the fixture. Please contact the factory if this occurs.
To reset a Timeout Condition
Set the Speed Dial to minimum Speed for controlled startup.
Press one of the Halt buttons and release. This will reset the timeout timer.
Slowly increase the speed. Press the ESC key if necessary to reverse the direction of rotation
so that the fixture is going back to 0 degrees (Home).
Monitor the travel back and forth to see if the problem still exists. If so please contact the
factory.
Home Position
The 'Home' position of the fixture is when the open section of the gear is at 12 O'clock.