Daily Inspections - Takara Belmont RS SWING Operating Manual

Table of Contents

Advertisement

6
After checking that the strainers have been fastened properly, open the stop valves.
Check that there are no water leaks from the check valve.
7
Mount the Rear cover onto the main unit.
<Checking for water leakage>
Open the rear cover once per week (measure):
・ Check that water is not leaking onto the floor.
・ Check that there is no water leakage inside of the basin unit.
If there is water leakage, the basin unit or pipes in the rotat ion arm may be damaged, so contact the
nearest dealer or Takara Belmont directly.
■ Stop Valve Knob
Open the Stop Valve at the beginning of the day and close it at the end
of the day.
■ Water removal (by removing the drain plug)
In cold regions where freezing can be expected, when you feel 
drain empties slowly, or when you accidentally drop something 
in the drain, remove the drain plug and remove remaining water.
In cold regions, always drain the water as a measure to
prevent freezing. Failure to follow this instruction may cause
water leakage.
1
Prepare a container for collecting water.
2
Hold the container under the basin and loosen the drain plug to take it off the unit.
3
After water removal is finished, tighten back the drain plug into the unit.
●Make sure to tighly tighten the drain plug. Otherwise,
it may cause water leakage.
Caution
●Immediately wipe off any water spilled on the floor.
●To ensure that this product can be used for a long period of time, follow the procedures outlined in
"Procedures for Daily Inspections" on page 26 to 27 of this instruction manual.
Always inspect this product following the procedures outlined in "Procedures for Daily Inspections".
Continuing to use this product without performing the daily inspections may cause malfunctions or
accidents.

Daily Inspections

21
Open
Stop Valve
Tighten
Loosen
Close
Knob
Basin
Drain Plug
Container for
collecting water