** Enter Setup

Set Length Range for Code 93

The engine can be configured to only decode Code 93 barcodes with lengths that fall between (inclusive)
the minimum and maximum lengths.
The supported maximum length is 255 characters. If minimum length is set to be greater than maximum
length, the engine only decodes Code 93 barcodes with either the minimum or maximum length. If
minimum length is same as maximum length, only Code 93 barcodes with that length are to be decoded.
Set the Minimum Length
Set the Maximum Length
Example: Set the engine to decode Code 93 barcodes containing between 8 and 12 characters.
1. Scan the Enter Setup barcode.
2. Scan the Set the Minimum Length barcode.
3. Scan the numeric barcode "8". (See the Digit Barcodes section in Appendix)
4. Scan the Save barcode. (See the Save/Cancel Barcodes section in Appendix)
5. Scan the Set the Maximum Length barcode.
6. Scan the numeric barcode "1".
7. Scan the numeric barcode "2".
8. Scan the Save barcode.
9. Scan the Exit Setup barcode.