Hitachi E-U Series Instruction Manual page 10

Vortex blower

Advertisement

Do not use motor hooks.
Fig.3.2 VB-040 to 080-E2
2. Installation Direction
In order to keep the shaft of the Vortex Blower level, mount the Vortex Blower
horizontally (see Horizontal Installation below).
Wall or upright installation is possible for models VB-019(S)-E-U or smaller. In these
instances, verify that blower unit faces downward (see Vertical Installation I below).
Do not perform vertical installation VB-030E-U or larger.
Do not perform vertical installation as shown in Vertical Installation II.
Motor
Unit
Horizontal Installation
3. Installation Location
Installation of the Vortex Blower should be indoors.
Eyebolt
Blower
Unit
Vertical Installation I
(Do not perform this installation
on VB-030E-U and larger)
Eyebolt
Do not use motor hooks.
fig.3.3 VB-110-E2
Upper Part
Motor
Unit
Blower
Unit
Lower Part
- 10 -
Less than 60°
Upper Part
Blower Unit
Lower Part
Vertical Installation II