Download Print this page

Installation - Hitachi E-U Series Instruction Manual

Vortex blower

Advertisement

3. INSTALLATION

1. Lifting the Vortex Blower
To lift the Vortex Blower by crane, please review the table and illustration below.
Model
VB-001SE-U,
VB-002SE-U,
VB-002SE-U,
VB-004(S)E-U,
VB-007(S)E-U
VB-019(S)E-U,
VB-030E-U
VB-040-E2
VB-060-E2,
VB-080-E2
VB-110-E2
NOTES:
Use the eyebolt on the motor housing for Vortex Blower model VB-019(S)E-U and VB-030E-U.
Use the eyebolt on the blower casing for Vortex Blower model VB-040-E2.
Use the eyebolt on the bracket for Vortex Blower model VB-060-E2 to VB-110-E2.
Do not use the motor hooks constructed on the motor housing. This motor hooks can break
and cause damage to the Vortex Blower.
Vortex Blower Hangar Construction Table
Motor
No hanger
Eyebolt on the housing
Motor hooks on housing
Do not use to lift
(See fig.3.1)
Motor hooks on housing
Do not use to lift
(See fig.3.1)
Motor hooks on housing
Do not use to lift
(See fig.3.1)
Do not use the motor hooks.
Fig.3.1 Strictly Prohibited
Blower
No hanger
No hanger
Eyebolt on the casing
Eyebolt on the bracket
Eyebolt on the bracket
- 9 -
Proper Lifting Procedure
By Hand
Use eyebolt
Use eyebolt
(See fig.3.2)
Use eyebolt
(See fig.3.2)
Eyebolt and lope
(See fig. 3.3)

Hide quick links:

Advertisement

loading