Installation

Installation
Set Up
NOTICE
Do not over tighten TLM into tank bung. Over
tightening can cause permanent damage and
result in inaccurate readings.
Do not use the TLM with pressurized tanks. Using
the TLM in a pressurized tank will damage the
TLM.
Do not use thread sealant or adhesive. Many of
these products are chemically incompatible with
the ABS plastic.
Register TLM to Tank in Pulse
Level Software
Navigate to URL: level.gracopulse.com
This device requires access to a cellular network to
work, and can be activated in Pulse Level. Refer to
Pulse Level terms of service in the About section of the
software.
After creating user, organization, branch and site,
navigate to Devices (located in the upper right corner of
the screen). Associate the device to your organization
by entering the serial number. When you create a tank
for the site, the device will be assignable.
Assign the TLM serial number to a tank in Pulse Level.
2
Activation
1. Hold the magnet (supplied) to the Hot Spot directly
under the LED to activate the device (F
F
. 1
IG
2. Keep holding the magnet to the Hot Spot. The LED
will flash green, and then flash red. Then the red
light will stay lit.
3. Remove the magnet.
4. While the red light is illuminated, a series of beeps
occur as the device connects.
5. Successfully connecting is indicated by a
high/low/high series of beeps that indicate the data
is being sent to Pulse Level. The LED turns green
after data is successfully sent.
6. Once activated, the device uploads readings at
scheduled times, if assigned to a tank in Pulse
Level.
• The device measures the tank liquid level.
. 1).
IG
LED light
Hot Spot
3A8551B