Glass cleaning
With a cold stove, clean the glass with a cloth and glass cleaner.
Note: there are stove glass cleaning products available on the market.
Cleaning the tube heat exchanger:
During operation, dust and soot are deposited on the surface of the heat
exchanger tubes. To ensure smooth operation throughout
the season, it is advisable to periodically clean the heat exchanger when the
stove is cold. Using the cold handle, extract the scraper rod and firmly move
the scraper back and forth.
Once you have finished cleaning the exchanger, push the scraper into the grille
(never leave it removed).

Combustion chamber cleaning

To clean the ash drawer, proceed as follows:
step
action
The stove requires a simple yet frequent cleaning in order to guarantee suitable yield and regular operation. Vacuum the
1
combustion
chamber every day using a bin ash vacuum, making sure that the ashes are completely cold.
Combustion chamber
Cleaning the pellet tank

To clean the pellet tank, proceed as follows:

step
action
1
Periodically remove the wood sawdust accumulated on the bottom of the tank, using a vacuum cleaner.
Extraction duct cleaning
Periodically check that the extraction duct is free from obstructions (dust, animal hair ...) and remove them if necessary.