Maintenance
Item
Check
Product safety
Before each use
labels
Trigger adjust-
Before each use
ment
Airless hose
Before each use
Suction tube
Before each use
Bypass tube
Before each use
Suction filter
Before each use
and every 5 gal.
Gun filter
Before each use
Roller nap
Before each use
Outlet valve
Spray tip
Before each use
www.chpower.com

Maintenance Chart

Replace
As required
As required
As required
Every 100 gal.
or more often if
required
Every 100 gal.
As required
Every 100 gal.
Every 20-75 gal.
12
Detail
Notes
See parts listing for
location of product
safety labels and relat-
ed part numbers.
Make sure gun shuts
off while spraying.
Read information on
the hang tag attached
to the high pressure
hose for instructions
on maintenance.
Check for nicks and
cuts.
Check for nicks and
cuts.
Do not attempt to
clean gun filter, only
replace.
Use 3/4" wrench –
torque to 150 in-lbs.
Use 13/16" wrench –
torque to 135 in-lbs.