Multitech Conduit IP67 200 Series Hardware Manual

200 base station
Hide thumbs Also See for Conduit IP67 200 Series:
Table of Contents

Advertisement

Quick Links

®
Conduit
IP67 Series 200 Base
Station
MTCDTIP2 Hardware Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Conduit IP67 200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Multitech Conduit IP67 200 Series

  • Page 1 ® Conduit IP67 Series 200 Base Station MTCDTIP2 Hardware Guide...
  • Page 2 Legal Notices The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage.
  • Page 3: Table Of Contents

    CONTENTS Contents Chapter 1 – Product Overview ..........................5 Build Options................................. 5 Documentation Overview ............................. 5 Developer Documentation............................5 Power over Ethernet (PoE) ............................6 Chapter 2 – Specifications and Related Information ....................7 Dimensions..................................7 Specification.................................. 8 LEDs and Connectors ..............................10 LEDs...................................
  • Page 4 CONTENTS REACH Statement ............................... 21 Registration of Substances............................21 Information on HS/TS Substances According to Chinese Standards (in Chinese) ............22 Information on HS/TS Substances According to Chinese Standards ................. 23 Appendix A – Safety Statements ..........................24 English ..................................24 Bulgarian ..................................
  • Page 5: Chapter 1 - Product Overview

    LTE Cat 4 mLinux Programmable Base Station, 8-channel, 868 MHz with internal LoRa antenna and internal cellular antenna. Documentation Overview The following documents are available at https://www.multitech.com/brands/conduit-ip67-200. Select your model to find the documents specific for that device. Document Description...
  • Page 6: Power Over Ethernet (Poe)

    PRODUCT OVERVIEW For mLinux getting started and advanced information, go to http://www.multitech.net/developer/software/mlinux/ For advanced mPower information, go to http://www.multitech.net/developer/software/aep/ For LoRa information, http://www.multitech.net/developer/software/lora/ Power over Ethernet (PoE) For information on using and troubleshooting PoE, refer to the PoE Application Note https://www.multitech.com/documents/publications/application-notes/S000678.pdf...
  • Page 7: Chapter 2 - Specifications And Related Information

    SPECIFICATIONS AND RELATED INFORMATION Chapter 2 – Specifications and Related Information Dimensions ® Conduit IP67 Series 200 Base Station MTCDTIP2 Hardware Guide...
  • Page 8: Specification

    SPECIFICATIONS AND RELATED INFORMATION Specification Category Description General Standards LoRaWAN 1.0.2 specifications LTE FDD Cat 4, 3GPP release compliant (-L4E1 models only) HSPA+ with GPRS fallback (-L4E1 models only) 256MB Flash 256MB Radio Frequency ISM Band 868 MHz ISM band for Europe 4G/LTE 4G: 1800 (B3), 2600 (B7), 800 (B20), 2100 (B1), 900 (B8), 700 (B28A) 3G: 2000 (B1), 1800 (B3), 900 (B8)
  • Page 9 SPECIFICATIONS AND RELATED INFORMATION Category Description EMC and Radio EN 55032 Class A Compliance EN 301 489-3 V2.1.1 for RED EN 301 489-1 V2.2.0 for RED EN 301 489-52 V1.1.0 Harmonized standard for cellular RED EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1 EN 300 328 V2.1.1 EN 301 489-19 EN 301 511 V9.0.2...
  • Page 10: Leds And Connectors

    SPECIFICATIONS AND RELATED INFORMATION LEDs and Connectors Connector Description Ethernet Port Ethernet port with IP67 rated cable gland. Grounding Stud Connector for ground wire. SIM Slot and LEDs Under a plastic cover. For all models, LEDs. For cellular models, a SIM holder (3FF micro SIM).
  • Page 11: Reset Button

    SPECIFICATIONS AND RELATED INFORMATION Reset Button You need: A slim screwdriver (1 or 2mm), paperclip, or similar thin object that can fit into the reset hole. The following is the default condition for the RESET button on the device. You can program a change to the behavior of the button if needed.
  • Page 12: Ethernet Models

    SPECIFICATIONS AND RELATED INFORMATION Voltage Power Down Cellular Call Average TS Pulse Total Inrush Total Inrush Mode via Measured Average Peak Charge Charge Radio Connection Current at Current for measured in DURATION Command (No Data) Max Power HSDPA/ LTE MilliCoulombs during Powerup (INRUSH...
  • Page 13: Chapter 3 - Labels

    (2) this device must accept any interference received, including interference that may cause undesired operation. The label shown is not the actual size. 1 - MultiTech Model Identification. 2 - MultiTech Ordering Part Number. 3 - Device Node Number 4 - IMEI Number 5 - UUID Label images are not actual size.
  • Page 14: Chapter 4 - Safety Notices

    PoE range for the MTCDTIP2 is 42.5-57 VDC.Any PoE voltages outside this range have not been evaluated by UL or MULTITECH. The end user supplies the PoE cable. If the cable is to be used outdoors, the cable must be certified for outdoor location.
  • Page 15: Installation Safety

    PoE standard. La plage PoE pour le MTCDTIP2 se situe entre 42,5 et 57 VDC. Toute tension PoE en dehors de la plage indiquée n'a pas été évaluée par UL ou MULTITECH. L'utilisateur final fournit le câble PoE. Ce câble doit être adapté à un emplacement extérieur. Il s'agit d'un appareil 802.3at de type 2.
  • Page 16: User Responsibility

    Note: MultiTech recommends inspecting the mounting hardware every 3-6 months to ensure it has not become loose or damaged due to weather conditions (such as lightning or wind) or a corrosive environment (such as saltwater).
  • Page 17: Sécurité Relative Aux Appareils À Radiofréquence (Rf)

    SAFETY NOTICES Operating your device close to other electronic equipment may cause interference if the equipment is inadequately protected. Observe any warning signs and manufacturers’ recommendations. Different industries and businesses restrict the use of cellular devices. Respect restrictions on the use of radio equipment in fuel depots, chemical plants, or where blasting operations are in process.
  • Page 18 SAFETY NOTICES Stop the pacemaker from delivering the stimulating pulses that regulate the heart's rhythm. Cause the pacemaker to deliver the pulses irregularly. Cause the pacemaker to ignore the heart's own rhythm and deliver pulses at a fixed rate. Based on current research, cellular devices do not pose a significant health problem for most pacemaker wearers. However, people with pacemakers may want to take simple precautions to be sure that their device doesn't cause a problem.
  • Page 19: Chapter 5 - Regulatory Information

    Council Directive 2014/35/EU on the harmonization of the laws of Member States relating to Electrical Equipment designed for use within certain voltage limits. MultiTech declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The declaration of conformity may be requested at https://www.multitech.com/landing-...
  • Page 20: Chapter 6 - Environmental Notices

    Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase. The WEEE Directive covers all MultiTech products imported into the EU as of August 13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements.
  • Page 21: Restriction Of The Use Of Hazardous Substances (Rohs)

    2015/863 of the European Parliament (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment - RoHS 3). These MultiTech products do not contain the following banned chemicals Lead, [Pb] < 1000 PPM Mercury, [Hg] <...
  • Page 22: Information On Hs/Ts Substances According To Chinese Standards (In Chinese)

    ENVIRONMENTAL NOTICES Information on HS/TS Substances According to Chinese Standards (in Chinese) 依 依 照 照 中 中 国 国 标 标 准 准 的 的 有 有 毒 毒 有 有 害 害 物 物 质 质 信 信 息 息 根据中华人民共和国信息产业部...
  • Page 23: Information On Hs/Ts Substances According To Chinese Standards

    ENVIRONMENTAL NOTICES Information on HS/TS Substances According to Chinese Standards In accordance with China's Administrative Measures on the Control of Pollution Caused by Electronic Information Products (EIP) # 39, also known as China RoHS, the following information is provided regarding the names and concentration levels of Toxic Substances (TS) or Hazardous Substances (HS) which may be contained in Multi-Tech Systems Inc.
  • Page 24: Appendix A - Safety Statements

    SAFETY STATEMENTS Appendix A – Safety Statements The following are translations of key cautions and warnings from the Conduit IP67 Base Station 200 Series MTCDTIP2 Installation Guide. English CAUTION: Read installation instructions and safety information before starting Base Station installation. Do not connect power until directed to do so.
  • Page 25: Estonian

    SAFETY STATEMENTS Estonian ETTEVAATUST: Enne alusjaama paigaldust, tutvuge paigaldusjuhiste ja ohutusalase teabega. Ärge ühendage vooluvõrku enne, kui seda on selgesõnaliselt soovitatud. HOIATUS: Kui ühendasite seadme vooluvõrguga, siis võtke pistik enne jätkamist vooluvõrgust välja. Flemish OPGELET: Lees de installatie-instructies en veiligheidsinformatie voor u de installatie van het Basisstation start. U mag de stroom pas aansluiten wanneer u de instructie krijgt om dit te doen.
  • Page 26: Latvian

    SAFETY STATEMENTS Latvian UZMANĪBU: Pirms uzstādīt bāzes staciju, izlasiet uzstādīšanas norādījumus un drošības informāciju. Nepieslēdziet barošanu, kamēr nav sniegts atbilstošs norādījums. BRĪDINĀJUMS. Ja ierīcei ir pieslēgta barošana, pirms turpināt darbu, atvienojiet to. Lithuanian ATSARGIAI: Prieš pradėdami montuoti bazinę stotį, perskaitykite montavimo instrukciją ir saugos informaciją. Elektros maitinimą...
  • Page 27 SAFETY STATEMENTS VARNING! Om du har kopplat in strömmen till enheten ska du koppla ut den innan du fortsätter. ® Conduit IP67 Series 200 Base Station MTCDTIP2 Hardware Guide...
  • Page 28: Index

    INDEX Index LoRa................10 antenna connectors ............10 models................5 build options ..............5 POE..................6 power measurements ..........11 12 certifications..............8 Chinese hazardous substances Chinese version............22 English version ............23 radio frequency interference........16 Class A reboot ................11 Industry Canada ............19 receive sensitivity............8 connectors ..............10 reset ................11 reset button ..............10 restore factory defaults ..........11 RoHS................21...

Table of Contents