Order Code - CD Automation CD3000S2PH User Manual

Electric power control 10 to 90a
Hide thumbs Also See for CD3000S2PH:
Table of Contents

Advertisement

CD3000S
2PH from 10A to 90A

3.2 Order Code

CD3000S 2PH
CURRENT (A)
description
10A
15A
25A
35A
45A
75A
90A
OPERATING VOLTAGE (V)
description
From 24V to Max Load Voltage
MAX LOAD VOLTAGE (V)
description
480V
600V
AUXILIARY VOLTAGE (V)
description
NO Auxiliary Voltage supply
12÷24V with analog input / HB Alarm
INPUT
description
SSR from 4 to 30Vdc
Analog Input 0÷10V
Analog Input 4÷20mA
FIRING
description
Zero Crossing with SSR Input
4 cycles on + 4 off with Analog Input
8 cycles on + 8 off with Analog Input
16 cycles on + 16 off with Analog Input
New Code (example):
CD3000S 2PH
Old Code (example):
Operating
Current
Model
Voltage
(A)
CD3000S 2PH / 75A
/
1
2
3
4
D
S
2
_
4
5
6
Code
OLD code
0
1
0
10A
0
1
5
15A
0
2
5
25A
0
3
5
35A
0
4
5
45A
0
7
5
75A
0
9
0
90A
-
Code
OLD code
not in the code
_ _ _V
7
OLD code
Code
4
6
8
Code
OLD code
0
NO /
4
12:24 /
9
Code
OLD code
S
SSR /
A
0÷10V /
V
4÷20mA /
10
Code
OLD code
Z
ZC /
4
BF004 /
8
BF008 /
6
BF016 /
1
2
3
4
D
S
2
0
Max Load
Aux
Voltage
Voltage
(V)
(V)
(V)
400V
/
480V
/
12:24V / 4-20mA / BF008 /
5
6
7
8
_
_
-
_
_
CONTROL MODE
Note
description
1
Open loop
FUSES & OPTION
description
No Fuse / No Option
No Fuse / HB Option for SSR input
No Fuse / HB Option for analog input
1
External Fuse & Fuse Holder / No Option
External Fuse & Fuse Holder / HB Option
for SSR input
Note
External Fuse & Fuse Holder / HB Option
for analog input
FAN VOLTAGE
Note
description
No Fan for unit <75A
Fan 110V Option - for 75A and 90A units
Fan 220V Standard - for 75A and 90A units
Note
APPROVALS
description
2,3
CE EMC for European Market
CE EMC + cUL us listed
Note
MANUAL
description
3,5
None
3,5
Italian
English
German
Note
French
IP PROTECTION
description
Standard IP20 (all unit excluded 45A, 75A,
90A)
External IP20 protection for size S7/S8
(45A, 75A, 90A)
(1)
For 10A 600V and for 90A cUL us not available
(2)
Necessary with 0÷10V - 4÷20mA or HB alarm
(3)
Option available from 45 to 90A
(4)
IP20 is standard on all units with exception of S7 and S8 size (45-75-90A).
To complain IP20 use "P" option at digit 16
HB option not available with UL approval
(5)
5
6
7
8
7
5
-
4
4
Input
Firing
Fuses
EF
12
User's manual
9
10
11
12
13
_
_
_
_
_
11
Code
0
12
Code
0
1
1
F
2
2
13
Code
0
1
2
14
Code
0
L
15
Code
0
1
2
3
4
16
Code
0
P
9
10
11
12
13
V
8
0
1
2
HB
EP
Approvals
Option
Option
/
HB
/
EP
/
14
15
16
_
_
_
OLD code
Note
not in the code
OLD code
Note
NF / -
NF / HB
5
5
EF / -
EF / HB
5
EF / HB
5
OLD code
Note
- /
110VFAN/
not in the code
OLD code
Note
- /
UL /
OLD code
Note
NM
IM
EM
GM
FM
OLD code
Note
- /
EP /
14
15
16
0
2
P
Manual
-
/
EM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CD3000S2PH and is the answer not in the manual?

Subscribe to Our Youtube Channel