Technical documentation
GIGA X3c
220
Supplied as standard
Z
Automatic speciality coffee machine
Z
Milk system cleaner, 100 ml
N
Z
Container for milk system cleaning
O
P
Z
Welcome Pack:
U
Instructions for use
U
Cleaning tablets
U
Air intake pipe
U
Silicone hose and connector
U
Spanner with hexagonal hole (for milk system)
GIGA X3c
JURA Elektroapparate AG, Kaffeeweltstraße 10, CH-4626 Niederbuchsiten, www.jura.com
Q
R
S
22
Festwasseranschluss
Restwasserablauf
-
-
Requirements for installation location
-
-
Rev.
Date
Vis.
Change Nr.
Change Description
Z
Horizontal surface that is not sensitive to water
GIGA X3c GII komplett
Z
Ambient conditions:
Jura Elektroapparate AG
0565 N 004
CH-4626 Niederbuchsiten
www.jura.com
T
U
U
Air humidity max. 80%
V
U
Ambient temperature 10–35°C
E The required connections at the customer's premises
must be carried out by an approved qualified person
before the JURA service technician can set up the GIGA
at your chosen location.
E Please make sure that the building connections are as
close as possible to the location of the machine (refer
to length of connection pipes).
Always note the information in the instructions for use
for your coffee machine (Chapter 1 "Preparing and using
for the first time" – "Requirements for first-time use" /
"Setting up the machine").
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Created
D. Kayser
25.06.2018
Released
D. Kayser
25.06.2018
System "E"
Volume
Format
Scale
Unit:
A0
1:2
16
mm
Revision / Version
Sheet
00-00
1 / 1
W
25.06.2018 d.kayser
1 / 3

Advertisement

loading

Summary of Contents for Jura GIGA X3c

  • Page 1 E The required connections at the customer’s premises Cleaning tablets must be carried out by an approved qualified person Air intake pipe before the JURA service technician can set up the GIGA Silicone hose and connector at your chosen location. Spanner with hexagonal hole (for milk system)
  • Page 2 To building CLARIS connection pipe (G 3/8"; 1.5 m; optional) Restwasserablauf Tresterdirektabwurf Socket 230 V / 10 A JURA water-filtering system (optional) (height max. 525 mm; Filter width max. 175 mm; Drain, siphon distance to ground min. 40 mm) To building...
  • Page 3 Restwasserablauf Tresterdirektabwurf E Minimum distance between hole and machine: 40 mm Hole for the coffee grounds disposal function Festwasseranschluss Position of tube section for coffee grounds disposal Restwasserablauf Tresterdirektabwurf Hole diameter: min. 70 mm GIGA X3c 3 / 3 202003...

This manual is also suitable for:

153981401215230