Unpacking And Storage - CanadianSolar CS3U-P Installation Manual

Standard solar modules
Hide thumbs Also See for CS3U-P:
Table of Contents

Advertisement

-26 to -30 / -14 to -22
-31 to -35 / -23 to -31
-36 to -40 / -32 to -40
Alternatively, a more accurate correction factor for the
open-circuit voltage can be calculated using the following
formula:
��
= �� − ��
Voc
T (°C) is the lowest expected ambient temperature at the
system installation site.
α
(%/°C) is the voltage temperature coefficient of the
Voc
selected module (refer to corresponding datasheet).
Electrical calculations and design must be performed by a
competent engineer or consultant.
Please contact Canadian Solar's technical support team
for additional information pertaining to engineering
optimization and approval of project specific module
string lengths.

4.0 UNPACKING AND STORAGE

PRECAUTIONS
 Modules should be stored in a dry and ventilated
environment to avoid direct sunlight and moisture. If
modules are stored in an uncontrolled environment,
the storage time should be less than 3 months and
extra precautions should be taken to prevent
connectors from being exposed to moisture or sunlight,
like using connector endcaps.
 When unloading modules pallets from containers,
please use a fork lift to remove the module pallets, and
the forklift should be close to the ground in order to
avoid the top of module pallets touching the top of the
cabinet door. The thickness of forklift teeth should be
less than 75mm, and the length of the forklift teeth
should be longer than 2300mm, when unloading the
module pallets with short side. For unloading CS7N-MS
and CS7L-MS modules, the length of the forklift teeth
should be longer than 1250mm and the width of forklift
teeth should be wider than 600mm (from outer edge to
EN-Rev IM/GN-AM-EN/2.71 Copyright © June, 2021. CSI Solar Co., Ltd.
× (���� − ��)
������
1.21
1.23
1.25
outer edge ).
 Unpack module pallets carefully, following the steps
shown on the pallet. Unpack, transport and store the
modules with care.
 Modules must always be unpacked and installed by two
people. Always use both hands when handling modules.
Do not
lift modules by their wires or junction box, lift
them by the frame.
 Stacks of modules should contain no more than 12
modules, and the frames should be aligned.
Do not
place excessive loads on the module or twist the
module frame.
Do not
stand, step, walk and/or jump on modules
under any circumstances. Localized heavy loads may
cause severe micro-cracks at cell level, which in turn
may compromise module reliability and void Canadian
Solar's warranty.
Do not
support the module by the backsheet when
handling or installing the module.
Do not
carry modules on your head.
Do not
drop or place objects (such as tools) on the
modules.
Do not
use sharp instruments on the modules.
| 5
www.csisolar.com

Advertisement

Table of Contents
loading

Table of Contents