Page 1
CUSTOMER SERVICE NORTH & CENTRAL AMERICA DOSATRON INTERNATIONAL INC. 2090 SUNNYDALE BLVD. CLEARWATER - FL 33765 - USA Tel. 1-727-443-5404 / 1-800-523-8499 - Fax 1-727-447-0591 Site web: www.dosatronusa.com MANUFACTURED BY DOSATRON INTERNATIONAL S.A.S. Certified QEH&S System Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE Tel.
Page 4
DOSATRON water-powered metering pumps. Over time this DOSATRON will prove itself to be a most faithful ally. A few regular maintenance operations will guarantee operation in which the word “breakdown” will no longer be heard.
Characteristics ................8 Dimensions ................8 INSTALLATION Precautions ................11 Installation of the Dosatron ............. 14 Changing the dosing scale ............. 16 Connecting the suction hose D40MZ3000 model ....18 Connecting the suction hose D40MZ2/5 model ..... 18 Installation tips ................ 19 Automatic device to prevent siphoning of the product ...
Weight: lbs [± kg] 7.3 [3,3] 7.3 [3,3] 7.3 [3,3] PARCEL COMPOSITION: 1 DOSATRON/1 mounting bracket for DOSATRON/1 suction hose for concentrate/1 strainer/ 1 quick start guide PACKAGING DIMENSIONS: 26 3/8” x 8 7/8” x 8 1/16” [67 x 22,5 x 20,5 cm] PARCEL WEIGHT: ~ 12.1 US lbs [5,5 kg approx.]...
Page 10
The solution produced is then propelled downstream. The dose of injected product is always proportional to the volume of water passing through the Dosatron, regardless of variations in flow or pressure in the water supply line. Motor piston...
Page 13
DOSATRON adjustments to obtain the desired slow closing solenoid valves. dosing. - In the case where a DOSATRON - An airtightness problem, an serves several sectors, activate impurity or a chemical attack on the solenoid valves simultaneously...
Page 14
DOSATRON. Annually replace the dosing part seals and the product suction hose. 6-SERVICE - This DOSATRON was tested prior to packaging. - Repair sub-assemblies and sachets of seals are available. - Do not hesitate to call your distributor or DOSATRON for any after-sales services.
Page 16
3 kg.m (reminder: 1 N.m = 0.1 DaN.m) The DOSATRON can be connected to the water supply line by means of 40 mm interior diameter flexible pipes fixed with swivel fittings 1 1/2” [Ø 40 x 49 mm]. Ensure that the water flows in the direction of the arrows (water direction) on the appliance.
CHANGING THE DOSING SCALE The DOSATRON dosing rate can be adjusted according to two scales: percentages and ratios. These scales are positioned on either side of the dosing part (Fig. 2). Depending on the liquid circulation direction in the hydraulic installation, and on the direction in which the dosing pump is mounted on its bracket, it may be necessary to change the orientation of this scale.
CONNECTING THE SUCTION HOSE D40MZ3000 MODEL The DOSATRON is delivered with a suction hose (to be adjusted as necessary) enabling its use with a large capacity container. This hose must be fitted with the strainer and ballast. NOTE: The maximum suction height is 4 metres [13 ft].
If your flow is above DOSATRON limits, see the § OVERFLOW. To prolong the service life of the DOSATRON, it is advisable to fit an upstream filter (e.g. 300 microns - 60 mesh depending on your water quality). This precaution is essential if the water contains impurities or particles, especially if the water comes from a well or it is surface water.
Page 21
OVERFLOW (as an indication) If your DOSATRON clacks more than 44 times in 15 seconds, (i.e. 22 cycles) you are at the upper flow capacity limit. Beyond this select a DOSATRON with a higher water flow capacity.
- Slowly open the Dosatron By-pass valves and close the main valve - Slowly open the fast priming valve situated downstream of the Dosatron. - Operate the DOSATRON until the product to be dosed rises in the dosing part (the product is visible through the plastic hose), then close the fast priming valve.
FEET OPTIONS If necessary, or if a wall installation is impossible, the D9 series Dosatron may be installed on feet using Kit 8EQ001 (Fig.16) : - Insert each foot in the corresponding holes on the bracket supplied with the dosing pump and the bracket included in the kit - Secure each foot using the 4 screws supplied.
Maintenance Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. RECOMMENDATIONS 1 - When using soluble products dissolved in stock solutions, contact manufacturers/distributors to verify the real solubility level of oral powders. It is preferable to use a Dosatron with a high dosing rate to guarantee a sufficient pre-dilution rate for powders.
DRAINING THE DOSATRON (in the context of keeping it frost-free) For complete maintenance of the DOSATRON, or to protect it from frost, draining may be necessary. - Turn off the water inlet and allow the pressure to drop to zero.
§ PRECAUTIONS. Before dismantling, and to avoid any contact with the dosed products, operate the DOSATRON by aspirating clear water to rinse the hose and the dosing part. - Unscrew the nut at the bottom of the dosing part (Fig.
DISMANTLING/REFITTING THE DOSING PART Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
CHANGING THE DOSING PART SEALS D40MZ3000 MODEL Frequency: at least once per year. Contact DOSATRON, or a dealer to select the appropriate seal kit for your dosing pump. For dismantling the dosing part, follow the instructions in the § DISMANTLING/REFITTING THE DOSING PART.
CHANGING THE DOSING PART SEALS D40MZ2/5 MODEL Frequency: at least once per year. Contact DOSATRON, or a dealer to select the appropriate seal kit for your dosing pump. For dismantling the dosing part, follow the instructions in the § DISMANTLING/REFITTING THE DOSING PART.
DISMANTLING/REFITTING THE DOSING PISTON D40MZ3000 MODEL Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
CLEANING AND REFITTING THE SUCTION VALVE Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
CHANGING THE MOTOR PISTON (unpressurised) Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
Page 42
KNOW YOUR FLOW A SIMPLE METHOD THE DOSATRON IS COMPOSED OF: In its backwards and forwards movement, the motor piston clacks: A volumetric piston hydraulic motor driving: a dosing piston 2 clacks = 1 motor Once in the Once in the...
Page 52
This document does not form a contractual obligation and is provided for information only. DOSATRON INTERNATIONAL reserves the right to alter its appliances at any time. CE Conformity Statement Document N° DOCE06050103 This Dosatron is in compliance with the European Directive 2006/42/CE.
Need help?
Do you have a question about the D40 and is the answer not in the manual?
Questions and answers