dosatron D40 Owner's Manual
Hide thumbs Also See for D40:

Advertisement

Quick Links

CUSTOMER SERVICE
NORTH & CENTRAL AMERICA
DOSATRON INTERNATIONAL INC.
2090 SUNNYDALE BLVD. CLEARWATER - FL 33765 - USA
Tel. 1-727-443-5404 / 1-800-523-8499 - Fax 1-727-447-0591
Site web: www.dosatronusa.com
MANUFACTURED BY
DOSATRON INTERNATIONAL S.A.S.
Certified QEH&S System
Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE
Tel. 33 (0)5 57 97 11 11
Fax. 33 (0)5 57 97 11 29 / 33 (0)5 57 97 10 85
info@dosatron.com - www.dosatron.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for dosatron D40

  • Page 1 CUSTOMER SERVICE NORTH & CENTRAL AMERICA DOSATRON INTERNATIONAL INC. 2090 SUNNYDALE BLVD. CLEARWATER - FL 33765 - USA Tel. 1-727-443-5404 / 1-800-523-8499 - Fax 1-727-447-0591 Site web: www.dosatronusa.com MANUFACTURED BY DOSATRON INTERNATIONAL S.A.S. Certified QEH&S System Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE Tel.
  • Page 2 Owner’s manual...
  • Page 3 NOTES ........................................................................................................................................................................................................................................................................................................... © DOSATRON INTERNATIONAL S.A.S / 2...
  • Page 4 DOSATRON water-powered metering pumps. Over time this DOSATRON will prove itself to be a most faithful ally. A few regular maintenance operations will guarantee operation in which the word “breakdown” will no longer be heard.
  • Page 5 NOTES ......................................................................................................................................................................................................................................................................................................... © DOSATRON INTERNATIONAL S.A.S / 4...
  • Page 6: Table Of Contents

    Characteristics ................8 Dimensions ................8 INSTALLATION Precautions ................11 Installation of the Dosatron ............. 14 Changing the dosing scale ............. 16 Connecting the suction hose D40MZ3000 model ....18 Connecting the suction hose D40MZ2/5 model ..... 18 Installation tips ................ 19 Automatic device to prevent siphoning of the product ...
  • Page 7: Marking/Identification/Characteristics

    A technical label on each side of the dosing pump body indicating the technical performances of the appliance. D40MZ3000BPVFII D40MZ3000BPVFII 19110152 19110152 REF. Serial No. © DOSATRON INTERNATIONAL S.A.S / 6...
  • Page 8: Codification Of The Reference

    3 000 Dosatron Range MZ : Adjustable Dosing (ratio or %) BP : Manual By-Pass option Dosing Seals VF: Acid additive - AF: Alkaline additive K : Kalrez Diver Seal option for concentrated acid additive © DOSATRON INTERNATIONAL S.A.S / 7...
  • Page 9: Characteristics

    Weight: lbs [± kg] 7.3 [3,3] 7.3 [3,3] 7.3 [3,3] PARCEL COMPOSITION: 1 DOSATRON/1 mounting bracket for DOSATRON/1 suction hose for concentrate/1 strainer/ 1 quick start guide PACKAGING DIMENSIONS: 26 3/8” x 8 7/8” x 8 1/16” [67 x 22,5 x 20,5 cm] PARCEL WEIGHT: ~ 12.1 US lbs [5,5 kg approx.]...
  • Page 10 The solution produced is then propelled downstream. The dose of injected product is always proportional to the volume of water passing through the Dosatron, regardless of variations in flow or pressure in the water supply line. Motor piston...
  • Page 11 Bleed Motor piston Mounting bracket Pump body Dosing piston Dosing sub-assembly Suction Suction hose valve + strainer + ballast Suction valve Hose © DOSATRON INTERNATIONAL S.A.S / 10...
  • Page 12: Installation

    - Store the DOSATRON away from excessive heat sources and in winter away from frost. - Do not install the DOSATRON on the water pump suction circuit (risk of siphoning). © DOSATRON INTERNATIONAL S.A.S / 11...
  • Page 13 DOSATRON adjustments to obtain the desired slow closing solenoid valves. dosing. - In the case where a DOSATRON - An airtightness problem, an serves several sectors, activate impurity or a chemical attack on the solenoid valves simultaneously...
  • Page 14 DOSATRON. Annually replace the dosing part seals and the product suction hose. 6-SERVICE - This DOSATRON was tested prior to packaging. - Repair sub-assemblies and sachets of seals are available. - Do not hesitate to call your distributor or DOSATRON for any after-sales services.
  • Page 15: Installation Of The Dosatron

    INSTALLATION OF THE DOSATRON Fig. 1 © DOSATRON INTERNATIONAL S.A.S / 14...
  • Page 16 3 kg.m (reminder: 1 N.m = 0.1 DaN.m) The DOSATRON can be connected to the water supply line by means of 40 mm interior diameter flexible pipes fixed with swivel fittings 1 1/2” [Ø 40 x 49 mm]. Ensure that the water flows in the direction of the arrows (water direction) on the appliance.
  • Page 17: Changing The Dosing Scale

    CHANGING THE DOSING SCALE The DOSATRON dosing rate can be adjusted according to two scales: percentages and ratios. These scales are positioned on either side of the dosing part (Fig. 2). Depending on the liquid circulation direction in the hydraulic installation, and on the direction in which the dosing pump is mounted on its bracket, it may be necessary to change the orientation of this scale.
  • Page 18 - If necessary, to see the pins better, unscrew the dosing adjustment sleeve as far as the middle of its travel.(Fig. 4) Fig. 5 - Manually retighten the fixing nut on the dosing part(Fig. 5) © DOSATRON INTERNATIONAL S.A.S / 17...
  • Page 19: Connecting The Suction Hose D40Mz3000 Model

    CONNECTING THE SUCTION HOSE D40MZ3000 MODEL The DOSATRON is delivered with a suction hose (to be adjusted as necessary) enabling its use with a large capacity container. This hose must be fitted with the strainer and ballast. NOTE: The maximum suction height is 4 metres [13 ft].
  • Page 20: Installation Tips

    If your flow is above DOSATRON limits, see the § OVERFLOW. To prolong the service life of the DOSATRON, it is advisable to fit an upstream filter (e.g. 300 microns - 60 mesh depending on your water quality). This precaution is essential if the water contains impurities or particles, especially if the water comes from a well or it is surface water.
  • Page 21 OVERFLOW (as an indication) If your DOSATRON clacks more than 44 times in 15 seconds, (i.e. 22 cycles) you are at the upper flow capacity limit. Beyond this select a DOSATRON with a higher water flow capacity.
  • Page 22: Automatic Device To Prevent Siphoning Of The Product

    (Fig. 11). - To put it into service, remove the red wrapper. Fig. 11 * example: case where the dosing pump outlet is lower than the inlet © DOSATRON INTERNATIONAL S.A.S / 21...
  • Page 23: Putting Into Service

    - Slowly open the Dosatron By-pass valves and close the main valve - Slowly open the fast priming valve situated downstream of the Dosatron. - Operate the DOSATRON until the product to be dosed rises in the dosing part (the product is visible through the plastic hose), then close the fast priming valve.
  • Page 24: Use

    - Screw or unscrew the dosing adjustment sleeve so that the 2 display eyelet dots are facing the desired dosing marker (Fig. 13). - Retighten the dosing locking nut (Fig. 14). Fig. 12 Fig. 13 Fig. 14 © DOSATRON INTERNATIONAL S.A.S / 23...
  • Page 25: Dosing Principle

    The DOSATRON may be fitted in its upper part with the function by-pass (optional equipment) : - By-pass in ON, the DOSATRON works and the concentrate is drawn up. - By-pass in OFF, the DOSATRON is stopped and does not draw up the product. Fig. 15 ©...
  • Page 26: Feet Options

    FEET OPTIONS If necessary, or if a wall installation is impossible, the D9 series Dosatron may be installed on feet using Kit 8EQ001 (Fig.16) : - Insert each foot in the corresponding holes on the bracket supplied with the dosing pump and the bracket included in the kit - Secure each foot using the 4 screws supplied.
  • Page 27: Maintenance

    Maintenance Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. RECOMMENDATIONS 1 - When using soluble products dissolved in stock solutions, contact manufacturers/distributors to verify the real solubility level of oral powders. It is preferable to use a Dosatron with a high dosing rate to guarantee a sufficient pre-dilution rate for powders.
  • Page 28: Draining The Dosatron

    DRAINING THE DOSATRON (in the context of keeping it frost-free) For complete maintenance of the DOSATRON, or to protect it from frost, draining may be necessary. - Turn off the water inlet and allow the pressure to drop to zero.
  • Page 29: Removing The Suction Hose

    § PRECAUTIONS. Before dismantling, and to avoid any contact with the dosed products, operate the DOSATRON by aspirating clear water to rinse the hose and the dosing part. - Unscrew the nut at the bottom of the dosing part (Fig.
  • Page 30: Removing/Refitting The Dosing Part

    DISMANTLING/REFITTING THE DOSING PART Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
  • Page 31: Changing Seals In The Dosing Part D40Mz3000 Model

    CHANGING THE DOSING PART SEALS D40MZ3000 MODEL Frequency: at least once per year. Contact DOSATRON, or a dealer to select the appropriate seal kit for your dosing pump. For dismantling the dosing part, follow the instructions in the § DISMANTLING/REFITTING THE DOSING PART.
  • Page 32 Fig. 23b Fig. 23c Fig. 23a Fig. 23d Fig. 23e Fig. 23f © DOSATRON INTERNATIONAL S.A.S / 31...
  • Page 33: Changing Seals In The Dosing Part D40Mz2/5 Model

    CHANGING THE DOSING PART SEALS D40MZ2/5 MODEL Frequency: at least once per year. Contact DOSATRON, or a dealer to select the appropriate seal kit for your dosing pump. For dismantling the dosing part, follow the instructions in the § DISMANTLING/REFITTING THE DOSING PART.
  • Page 34 Fig. 24e Fig. 24b Fig. 24f Fig. 24c Fig. 24a Fig. 24d © DOSATRON INTERNATIONAL S.A.S / 33...
  • Page 35: Removing/Refitting The Dosing Piston D40Mz3000 Model

    DISMANTLING/REFITTING THE DOSING PISTON D40MZ3000 MODEL Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
  • Page 36: Cleaning And Refitting The Suction Valve

    CLEANING AND REFITTING THE SUCTION VALVE Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
  • Page 37: Changing The Motor Piston

    CHANGING THE MOTOR PISTON (unpressurised) Before any maintenance on the DOSATRON, it is essential to refer to the § PRECAUTIONS. Before dismantling, and to avoid any contact with the products dosed, operate the DOSATRON by aspirating clear water to rinse the dosing part.
  • Page 38 © DOSATRON INTERNATIONAL S.A.S / 37...
  • Page 39: Troubleshooting

    No suction of product. Suction valve seal worn, Clean it or replace it. wrongly fitted or clogged. Plunger seal wrongly fitted, Clean it or replace it. clogged or swollen. Dosing pump body scratched. Replace it. © DOSATRON INTERNATIONAL S.A.S / 38...
  • Page 40 Position it correctly, clean body and the top. incorrectly or absent the seal groove or replace it. DOSATRON INTERNATIONAL DECLINES ALL RESPONSIBILITY IN THE EVENT OF USE THAT IS NOT COMPLIANT WITH THE INSTRUCTIONS FOR USE. © DOSATRON INTERNATIONAL S.A.S / 39...
  • Page 41: Limited Warranty

    DOSATRON INTERNATIONAL S.A.S appliances. This warranty does not cover defects found to be due to abnormal installation of the appliance, inappropriate use of tools, lack of maintenance or defective ©...
  • Page 42 KNOW YOUR FLOW A SIMPLE METHOD THE DOSATRON IS COMPOSED OF: In its backwards and forwards movement, the motor piston clacks: A volumetric piston hydraulic motor driving: a dosing piston 2 clacks = 1 motor Once in the Once in the...
  • Page 44 Annexes Curves...
  • Page 45 Pressure losses D40MZ3000...
  • Page 46 D40MZ2...
  • Page 47 D40MZ5...
  • Page 48 Viscosity limit D40MZ3000...
  • Page 49 D40MZ2...
  • Page 50 D40MZ5...
  • Page 52 This document does not form a contractual obligation and is provided for information only. DOSATRON INTERNATIONAL reserves the right to alter its appliances at any time. CE Conformity Statement Document N° DOCE06050103 This Dosatron is in compliance with the European Directive 2006/42/CE.

Table of Contents