ENTER SETUP MODE

TO ENTER SETUP MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON UNTIL
BLUE LIGHT IS PRESENT. RELEASE
BUTTON.
HOLD DOWN ELECTRONIC
OVERRIDE BUTTON
UNTIL SOLID BLUE LIGHT
PRESENT TO ADVANCE
RELEASE BUTTON.
7.1 SENSOR RANGE ADJUSTMENT MODE
Press and release electronic override button
to toggle through the settings
Blue light fl ashes when object is detected
Red lights signify range choices
W/C Bowl
Lights visible
Length
Sensing Distance
1 Red
20"
2 Reds
22"
3 Reds
24"
4 Reds
26"
5 Reds
28"
Step 7 - Making Adjustments (Optional: Only required if factory settings are not preferred)
7.1 Sensor Adjustment:
For Waterclosets:
Configure the sensing ranges by selecting the appropriate bowl length. Refer to Figure 6 for the
different bowl length settings.
The bowl length is the distance from the centre line of the valve to the lip of the bowl (see Figure 7).
To ensure the correct distance is selected, stand or place a target at the end of the bowl. Starting
with one illuminated red light, step through the distances until the blue light begins to flash. The
flashing light confirms that the sensor is configured for that bowl length.
NOTE: The W/C bowl length setting is NOT the sensing range. The advanced sensor activated flush
system uses multiple detection distances and the bowl length to react appropriately to different
usage patterns.
If no further length adjustments are desired, press and hold down the electronic override button for
5 seconds, until a solid blue light is present. Release the electronic override button to advance to
the next adjustment feature.
A blue and red light will be present. This mode is currently inactive and is designed for any future options.
To advance to the 24 Hour Flush, press and hold down electronic override button for 5 seconds until the solid blue light is present.
Release electronic override button, you are now in 24 Hour Flush configuration.
For Urinals:
Configure the sensing range by selecting the desired detection distance.
Each press and release of the electronic override button advances to the next length/distance. (See Figure 6 for a list of distances)
Start with one red visible light.
Stand or place a target at the desired detection distance, the top blue light will be flashing if an object is detected.
Press and release electronic override button to step through the distance options until the blue light begins to flash, indicating that
the target has been detected. The blinking blue light indicates that the sensor is configured for that length/distance.
The sensor is now set at your desired configuration.
If no further sensing range adjustments are desired, press and hold down the electronic override button for 5 seconds, until a solid
blue light is present.
Release electronic override button. You are now in 24 Hour Flush configuration.
7.2 24 Hour Flush Adjustment Mode:
When the 2 red lights are present - 24 hour flush is OFF.
When the 3 red lights are present - 24 hour flush is ON.
Press electronic override button to toggle between ON and OFF mode.
Exiting Set-Up Mode:
Can be accomplished in one of two ways;
1.
During the 24 Hour Adjustment feature, press and hold down electronic override button for 5 seconds until solid blue light is
present. Release electronic override button. All lights will be ON. Press and Hold the electronic override button (again) until JUST
the solid blue light is on, release the electronic override button.
2.
During all modes, valve will revert back to operation mode automatically if the electronic override button is not pressed within 3 minutes.
* After the last adjustment has been completed and the flush valve has returned to operation mode, there is a window of approximately 30
minutes where additional changes can be made. If desired adjustments are not made within 30 minutes, the batteries or hardwire converter
must be disconnected for 10 seconds and then re-connected to obtain another adjustment period. To make changes, begin at step #6 above.
INACTIVE MODE
(WC only - designed for future options)
Urinal
8"
12"
16"
20"
24"

EXIT SETUP MODE

TO EXIT SETUP AND RETURN TO
OPERATION MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON
UNTIL BLUE LIGHT IS PRESENT.
RELEASE BUTTON.
HOLD DOWN ELECTRONIC
OVERRIDE BUTTON UNTIL
SOLID BLUE LIGHT IS
PRESENT TO ADVANCE
RELEASE BUTTON.
7.2 24 HOUR FLUSH ADJUSTMENT
Press and release electronic override button to
toggle through the settings
No Blue light will be present
Red lights signify 24 Hour fl ush on or off
Lights visible
Presents
2 Reds
24 Hour Flush OFF
3 Reds
24 Hour Flush ON
www. s p e c s e l e c t . c o m
Page 6
ALL LIGHTS WILL BE ON, HOLD DOWN THE
ELECTRONIC OVERRIDE BUTTON (AGAIN)
UNTIL ONLY THE SOLID BLUE LIGHT IS ON,
RELEASE TO RETURN TO OPERATE MODE.
Fig. 7
Fig. 6
Bowl Length
212385 Rev. A