All major components requiring maintenance have guidelines listed in the respective operation manuals. Refer to
those individual operation manuals for other preventative maintenance and regular maintenance information.
Maintenance Table
Component
Compressed Air Filter
Compressor Inlet Air Filter Replace inlet air filter
Ozone Leak Sensor
ORP Sensor
Dissolved Ozone Monitor
Check Valves
Air Compressor
ODS-1H Destruct Unit
Injection Pump

Appendix B - Maintenance

Action
Replace filter element
Replace sensor
Replace sensor
Replacement flat cap
Replace
Rebuild compressor
Replace Catalyst
Replace/rebuild pump
Tim Interval
3 months/as needed
3 months/as needed
Annually
Annually
Annually
Annually
Annually
Annually
3-5 years
Part Number(s)
PR-8: Replacement filter
CP-Filter-4: Repl Element
SEN-1
ORP-Sensor
AS- Flat Cap
CVLP-4 and CVHP-8
CP-OG Rebuild
ODS-Catalyst
CM5-G Rebuild