Glen Dimplex System M Comfort Plus 16 kW Installation And Operating Instructions Manual

Air-to-water heat pump in integral design

Advertisement

Quick Links

System M
Comfort Plus 16 kW
16CHOIAOC6
16IHOIAOC6
Installation and
Operating Instruction
Air-to-Water
Heat Pump
in Integral Design
Order no.: DOK4x HOIAO CxDEN
Glen
Dimplex
Thermal
Solutions
Dimplex
EN · FD 9912

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the System M Comfort Plus 16 kW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Glen Dimplex System M Comfort Plus 16 kW

  • Page 1 Glen Dimplex Thermal Solutions Dimplex System M Comfort Plus 16 kW 16CHOIAOC6 16IHOIAOC6 Installation and Operating Instruction Air-to-Water Heat Pump in Integral Design Order no.: DOK4x HOIAO CxDEN EN · FD 9912...
  • Page 3: Table Of Contents

    Air-to-water heat pump 16 kW with domestic hot water English Table of contents Please read immediately...........................3 1.1 Intended use..................................... 3 1.2 Legal regulations and directives ............................3 1.3 Energy-efficient use of the heat pump..........................3 Intended use of the heat pump ........................4 2.1 Area of application..................................
  • Page 4 English Air-to-water heat pump 16 kW with domestic hot water 13 Diagrams ................................32 13.1 Characteristic curves heation 16 kW ..........................32 14 Product information as per Regulation (EU) No 813/2013, Annex II, Table 2 ........33 15 Warranty certificate............................35 16 Information on the use of data........................
  • Page 5: Please Read Immediately

    Air-to-water heat pump 16 kW with domestic hot water English Please read immediately 1.1 Intended use 1.3 Energy-efficient use of the heat pump This device is only intended for use as specified by the manu- facturer. Any other use beyond that intended by the manufac- By operating this heat pump you are helping to protect our en- turer is prohibited.
  • Page 6: Intended Use Of The Heat Pump

    English Air-to-water heat pump 16 kW with domestic hot water Intended use of the heat pump 2.1 Area of application The air-to-water heat pump is to be used exclusively for heating and domestic hot water. It can be used in new or existing heat- ing systems.
  • Page 7: Scope Of Supply

    Air-to-water heat pump 16 kW with domestic hot water English Scope of supply 3.1 Indoor unit Hydraulic systems (including a dual differential pressureless manifold) 50 l buffer tank * Actuator for 3-way reversing valve Refrigeration circuit 3-way reversing valve for generating domestic hot water 11) Heat exchanger refrigerant / heating water Regulated auxiliary circulating pump 12) Compressor...
  • Page 8: Domestic Hot Water Cylinder

    English Air-to-water heat pump 16 kW with domestic hot water 3.2 Domestic hot water cylinder 3.2.1 MDHW 232 (220 litres) Magnesium anode Maintenance opening Drainage domestic hot water cylinder Purging pipe heat exchanger Domestic hot water sensor pipe Connection kit (included) DOK4x HOIAO CxDEN ·...
  • Page 9 Air-to-water heat pump 16 kW with domestic hot water English 3.2.2 MDHW 335 (335 litres) Magnesium anode Maintenance opening Drainage domestic hot water cylinder Purging pipe heat exchanger Domestic hot water sensor pipe (high output capacity) Connection kit (included) Alternative domestic hot water sensor pipe (energy-opti- mised) Additional electric heater for domestic hot water (flange heater)
  • Page 10: Outdoor Unit

    English Air-to-water heat pump 16 kW with domestic hot water 3.3 Outdoor unit Evaporator Expansion valve Switch box Connection for refrigerant line DOK4x HOIAO CxDEN · FD 9912 www.gdts.one...
  • Page 11: Transport

    Air-to-water heat pump 16 kW with domestic hot water English Transport 4.1 Outdoor unit The casing panels must be dismantled in the order outlined be- low. A pallet should be used to transport the heat pump to its final The right side panel must be removed first. For this, loosen the installation location.
  • Page 12: Domestic Hot Water Cylinder

    English Air-to-water heat pump 16 kW with domestic hot water 4.3 Domestic hot water cylinder After the final positioning at the installation location, remove the transport fastening on the sprung floor of the compressor A pallet should be used to transport the heat pump to its final on both sides.
  • Page 13: Installation

    Air-to-water heat pump 16 kW with domestic hot water English Installation 5.1 Outdoor unit If multiple outdoor units are set up next to each other, the re- quired minimum distance at the side adds up. Ensure that the Among other things, when selecting the installation locations cold expelled air is not sucked in again.
  • Page 14: Indoor Unit And Domestic Hot Water Cylinder

    English Air-to-water heat pump 16 kW with domestic hot water 5.2 Indoor unit and domestic hot The minimum volume of the room where the heat pump is in- stalled must be no less than the following value depending on water cylinder the refrigerant quantity in the device: The indoor unit and domestic hot water cylinder must be in- Permissible...
  • Page 15: Assembly / Connection

    Air-to-water heat pump 16 kW with domestic hot water English Assembly / connection 6.1 Assembly of the refrigerant line Once the heat pump has been connected to the heating sys- tem, it must be filled, purged and pressure-tested. and electric wire When doing so, it must be ensured that all heating circuits and isolating valves are open and that the 3-way reversing valve is in The refrigerant lines and electric wires for connecting the in-...
  • Page 16: Domestic Hot Water Connection

    English Air-to-water heat pump 16 kW with domestic hot water Frost protection The following points must be observed when filling the system: Untreated filling water and make-up water must be of  A method of manual drainage should be provided for heat drinking water quality pumps which are exposed to frost.
  • Page 17: Temperature Sensor Connection

    Air-to-water heat pump 16 kW with domestic hot water English 6.5 Temperature sensor connection The following temperature sensors are already installed or must be installed additionally:  Outside temperature (R1) is (NTC-2) Return temperature (R2) installed (NTC-10)  Demand sensor (R2.2) installed (NTC-10) ...
  • Page 18: Electrical Connection

    English Air-to-water heat pump 16 kW with domestic hot water 6.6 Electrical connection 6.6.1 Circuit diagram Symbol legend, see cap. 6.6.2 on page 17 Equipment marking, see cap. 6.6.3 on page 17 DOK4x HOIAO CxDEN · FD 9912 www.gdts.one...
  • Page 19 Air-to-water heat pump 16 kW with domestic hot water English 6.6.2 Symbol legend 6.6.3 Equipment markings +A100 Refrigeration circuit Connector +A110 Outdoor unit +A200 Hydraulics /WPM Plug connection +A210 Master unit +A220 Expansion module WPM +A300 Electrical distribution system Compressor / refrigeration circuit +A350 Router +A400...
  • Page 20 English Air-to-water heat pump 16 kW with domestic hot water 6.6.4 Electrical connection general on-site. The floating NO contact of the utility blocking con- tactor (13/14) is wired to the hydraulic switch box and All connection cables must be provided on-site. The cable type must be connected on the relevant plug +A200-XK22 (cross-section, conductor type, etc.) must be chosen taking there.
  • Page 21: Refrigerant Pipe Connections

    Air-to-water heat pump 16 kW with domestic hot water English 6.7 Refrigerant pipe connections HINWEIS NOTE If the indoor unit is mounted 2.5 m or more metres higher or lower than the outdoor unit, a cooling technology specialist ATTENTION! must perform a separate check to ensure that the devices for Work on the system must only be performed by authorised conveying the oil up and down the pipes have been installed and qualified after-sales service technicians.
  • Page 22 English Air-to-water heat pump 16 kW with domestic hot water Step 3: Evacuation Connect the vacuum pump on the maintenance valve (with  Schrader). Run the vacuum pump until the relevant vacuum is  reached. An absolute pressure of at least 0.2 mbar must be achieved during evacuation.
  • Page 23: Commissioning

    Air-to-water heat pump 16 kW with domestic hot water English Commissioning 7.1 General 7.3 Procedure To ensure that commissioning is performed correctly, it should The heat pump is commissioned using the master unit or a only be carried out by an after-sales service technician author- smart device paired with the pump.
  • Page 24: Cleaning / Maintenance

    English Air-to-water heat pump 16 kW with domestic hot water Cleaning / maintenance 8.1 Maintenance It is then important that the system be thoroughly flushed using appropriate neutralising agents to prevent any damage from To protect the paintwork, avoid leaning anything against the being caused by cleaning agent residue remaining in the sys- device or putting objects on the device.
  • Page 25: Faults / Troubleshooting

    Air-to-water heat pump 16 kW with domestic hot water English Faults / troubleshooting This heat pump is a quality product and is designed for trouble- ATTENTION! free operation. In the event that a fault should occur, it will be Before opening the device, ensure that all circuits are discon- indicated on the master unit display.
  • Page 26: Device Information

    English Air-to-water heat pump 16 kW with domestic hot water 11 Device information 11.1 Device information heatpump Type and order code 16CHOIAOC6 16IHOIAOC6 Design System M Comfort Plus System M Comfort Plus Heat source Energy efficiency class high temperature Energy efficiency class low temperature Seasonal coefficient of performance (COP) for average climate 35 °C/ 55 °C 4.4 / 3.0 4.4 / 3.0...
  • Page 27 Air-to-water heat pump 16 kW with domestic hot water English Type and order code 16CHOIAOC6 16IHOIAOC6 Electrical connection Supply voltage / fusing / RCD type Compressor 1~/N/PE 230 V (50 Hz) / C25A / B 3~/N/PE 400 V (50 Hz) / C10A / B Pipe heater 1~/N/PE 230 V (50 Hz) / B32A / A 3~/N/PE 400 V (50 Hz) / B10A / A Control voltage / fusing via WPM...
  • Page 28: Device Information, Domestic Hot Water Cylinder

    English Air-to-water heat pump 16 kW with domestic hot water 11.2 Device information, domestic hot water cylinder Type and order code MDHW 232 MDHW 335 Technical data Enamelled steel complying with Enamelled steel complying with Material DIN 4753 DIN 4753 Cylinder volume litres Nominal volume...
  • Page 29: Dimension Drawing

    Air-to-water heat pump 16 kW with domestic hot water English 12 Dimension drawing 12.1 Dimension drawing outdoor unit www.gdts.one DOK4x HOIAO CxDEN · FD 9912...
  • Page 30: Dimension Drawing Indoor Unit

    English Air-to-water heat pump 16 kW with domestic hot water 12.2 Dimension drawing indoor unit DOK4x HOIAO CxDEN · FD 9912 www.gdts.one...
  • Page 31: Dimension Drawing Domestic Hot Water Cylinder Mdhw 232

    Air-to-water heat pump 16 kW with domestic hot water English 12.3 Dimension drawing domestic hot water cylinder MDHW 232 www.gdts.one DOK4x HOIAO CxDEN · FD 9912...
  • Page 32: Dimension Drawing Domestic Hot Water Cylinder Mdhw 335

    English Air-to-water heat pump 16 kW with domestic hot water 12.4 Dimension drawing domestic hot water cylinder MDHW 335 DOK4x HOIAO CxDEN · FD 9912 www.gdts.one...
  • Page 33: Dimension Drawing Legend

    Air-to-water heat pump 16 kW with domestic hot water English 12.5 Dimension drawing legend Outdoor unit Connection refrigerant line 12 x1 mm outdoor unit Connection refrigerant line 18 x 1 mm outdoor unit Condensate drain Feedthrough refrigerant lines and electric wires; con- densate hose Optional feedthrough refrigerant line 18 mm Optional feedthrough electric wires 12 mm...
  • Page 34: Diagrams

    English Air-to-water heat pump 16 kW with domestic hot water 13 Diagrams 13.1 Characteristic curves heation 16 kW Heat output in [kW] EN 14511 A7 W35...30 1,2 m³/h A7 W45...40 1,2 m³/h A7 W55...47 0,8 m³/h max. min. Air intake temperature in [°C] Power consumption (including proportion of pump output) [kW] Heating water temperature [°C] max.
  • Page 35: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 36 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 37: Warranty Certificate

    Air-to-water heat pump 16 kW with domestic hot water English 15 Warranty certificate Glen Dimplex Thermal Solutions It is possible to extend the warranty under certain conditions by tak- ing out a Care Basic warranty package (extension from 2 to 5 years).
  • Page 38: Information On The Use Of Data

    16 Information on the use of data IV. Information on products and new developments. It is very important to Glen Dimplex Thermal Solutions (GDTS) that your data is handled correctly. We should therefore like to GDTS will use your contact details on occasion to show you provide you with information on the data collected when oper- new products and innovations relating to smart homes.
  • Page 39: Declaration Of Conformity

    Air-to-water heat pump 16 kW with domestic hot water English 17 Declaration of conformity You can find and download the current CE conformity declaration at: https://gdts.one/m www.gdts.one DOK4x HOIAO CxDEN · FD 9912...
  • Page 40 Glen Dimplex Thermal Solutions Zentrale Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D-95326 Kulmbach T +49 9221 709-100 F +49 9221 709-339 dimplex@gdts.one www.gdts.one Geschäftsstelle Österreich Glen Dimplex Austria GmbH Hauptstraße 71 A-5302 Henndorf am Wallersee T +43 6214 20330 F +43 6214 203304 info@dimplex.at...

This manual is also suitable for:

16choiaoc616ihoiaoc6

Table of Contents