Technical Details - Pilz PSEN cs5.1 M12/8 Operating Manual

Sensor technology
Hide thumbs Also See for PSEN cs5.1 M12/8:
Table of Contents

Advertisement

PSEN cs5.1 M12/8

Technical details

General
Approvals
Sensor's mode of operation
Coding level in accordance with EN ISO 14119
Design in accordance with EN ISO 14119
Classification in accordance with EN 60947-5-3
Pilz coding type
Transponder
Frequency band
Max. transmitter output
Electrical data
Supply voltage
Voltage
Kind
Voltage tolerance
Output of external power supply (DC)
Max. switching frequency
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
PNOZmulti, PNOZelog, PSS
Max. inrush current impulse
Current pulse, A1
No-load current
Inputs
Number
Voltage at inputs
Input current range
Semiconductor outputs
OSSD safety outputs
Signal outputs
Switching current per output
Breaking capacity per output
Potential isolation from system voltage
Short circuit-proof
Residual current at outputs
Voltage drop at OSSDs
Conditional rated short circuit current
Lowest operating current
Utilisation category in accordance with EN 60947-1
Times
Test pulse duration, safety outputs
Operating Manual PSEN cs5.1 M12/8
1003419-EN-06
CE, EAC (Eurasian), ECOLAB, FCC, IC, TÜV, UL/
cUL
Transponder
Low
4
PDDB
Coded
122 kHz - 128 kHz
15 mW
24 V
DC
-20 %/+20 %
1 W
3 Hz
40 nF
40 nF
0,5 A
25 mA
2
24 V DC
1,6 - 3 mA
2
1
100 mA
2,4 W
No
yes
400 µA
1 V
100 A
2 mA
DC-12
150 µs
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

542 009542 059542 083