PSEN cs5.1 M12/8

Connection to Pilz evaluation devices

The safety switch PSEN cs5.1 M12/8 can be connected to Pilz evaluation devices, for ex-
ample.
Suitable Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
}
PNOZpower for safety gate monitoring
}
PNOZsigma for safety gate monitoring
}
PNOZ X for safety gate monitoring
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Make sure that the connection is made in accordance
with the specifications in the operating manual for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex-
ample:
}
PNOZ s3 and
}
PNOZmulti
PNOZ s3