Installation

Warning! Refer to Safety
chapters.
Assembly
Refer to the Assembly Instructions
for the installation.
Electrical installation
Warning! Only a qualified
person must do the electrical
installation.
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This oven is supplied without a main plug
and a main cable.
To access the electrical connections unscrew
the 2 T20 screws on the rear panel top and
take the panel out.

Product description

General overview
2
1
4
3
9
2
1
8
3
4
5
6
7
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also
refer to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
Control panel
1
Knob for the heating functions
2
Control knob
3
Temperature indicator
4
Air vents for the cooling fan
5
Grill
6
Lamp
7
Rating plate
8
Shelf positions
9
Section of the cable
(mm²)
3 x 0.75
3 x 1
3 x 1.5