Keep surrounding dry and clean.
environment, don't put liquid fileld containers on the device. Projector should be put in a water-proof housing
when operated outside.
Regularly open the device (see "cleaning" further down) to check for dust inside, or if fog fluid condenses in the
housing (if so rearrange hazer and/or laser position).
Operating temperature is 10~35°C. In a new installation, check after some 15-30 minutes whether the outlet air
gets too warm. Regularly check the inside for dust deposits, especially around the fans. Let laser cool off
10minutes after 2 hours of operation,to ensure maximum lifetime for the diode.
Distance between laser aperture and projection screen should be not less than 1 meter.
Do not turn device on and immediately off again frequently.
Do not look into the laser beam directly, especially not with optical instruments.
Do not touch the device with wet hands.
When the laser diode becomes dim or broken, please contact your dealer.
When returning laser to dealer/manufacturer always use original packaging.
Maintenance should be performed every 15-day period. See "cleaning" further down.
To ensure maximum lifetime of the laser:
Don't overheat the laser:
Always ensure good ventilation
Don't have stage lights (especially moving heads) directed towards the laser
Regularly clean the fans and the interior from dust
In a new installation check the temperature after 30 minutes of operation
Keep the laser dry
Make sure fog/hazer fluid doesn't condensate inside the laser - fog has to be in front of the laser – not
inside
A few days after (each new) installation, open the cover to check if fluids condensate inside
If fluids condensate inside, reposition the laser or fogger/hazer
Turn the device off, when not used. The diode is on, when the device is on. Even if it is not lit.
If the laser is equipped with a remote connector, connect an emergency switch to the Remote lock connector on
the backside, if no emergency switch is used, insert the 9 pin dongle instead. If the laser has no remote lock, use
an emergency switch in the mains connection.

Using the laser

Caution – use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the 9-pin connector on the
backside (pins 1 and 2). If you do not wish to connect an emergency switch, connect the 9-pin plug instead.
Depending on the mode selected (see below), laser light should come out of the opening on the front panel – be
careful.
Control panel
1
Power on/off
2
Power input: make sure the correct voltage is
used
3
DMX in/out
4
ILDA connector in/out
5
Safety switch: Laser on/off
6
Remotelock: connect emergency switch. If no
emergency switch is connected use the 9 pin plug
supplied.
MODE: select mode, or go up in menu
ENTER: confirm changes, or go down in menu
UP/ DOWN: change DMX address

Operating modes:

Automatic mode: built-in patterns are displayed
Music active: laser is controlled from built-in microphone
"DMXAddr": DMX512 mode-. Here you can change the DMX address:
"Open": change address
"Up" & "down": increase/decrease address
"Save": save new address
This unit should be keep dry, do not use in the rain or damp and dusty