Removal of Coils / Thermistors

6. Removal of Coils / Thermistors
Procedure
Step
1. Remove the electronic
expansion valve coil.
1
Pull the electronic
expansion valve coil
out.
2. Remove the thermistors.
Pull out the outdoor
1
heat exchanger
thermistor.
Slightly open the sound
2
blanket (outer).
28
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Outdoor heat exchanger thermistor
Sound blanket (outer)
Electronic
expansion
valve coil
(R9631)
The position of outdoor heat
exchanger thermistor is
different depending on the
model.
Outdoor heat exchanger
thermistor
(R17236)
You can remove the
thermistor ASSY with the
electrical box on.
(1) Disconnect [S90] from the
electrical box (main PCB).
(2) Release the thermistor
harness from the hook at the
bottom of electrical box.
(3) Pull out the clamp of the
thermistor harness from the
hole of the electrical box.
(R9633)
Si00-978
Points
(R9632)
Removal Procedure