Shutdown - Cornelius Energize 2 HC Operator's Manual

Undercounter cooler
Table of Contents

Advertisement

4.3

Shutdown

NOTICE!
The following describes how the operator or user can temporarily shut
down the unit (< 24 hours).
If the unit has to be shut down for a longer period (> 24 hours), this may
only be carried out by an expert, see chapter 1.3.3, as the unit has to be
cleaned and drained.
1. Close the CO
bottle valve; see documentation on the CO
2
2. Close the CO
shut off valves; see documentation on the CO
2
3. Close the valve of the water supply; see documentation on the water system.
4. Turn the compressor switch (Fig. 17/3) to position "0".
5. Turn the circulation pump switch (Fig. 17/2) to position "0".
6. Turn the carbonator pump switch (Fig. 17/1) to position
"0".
7. Pull the mains plug out of the earthed socket.
Cornelius Deutschland GmbH
Document no. TD1002000
Version 01/10/2019, Index 2
Operation
system.
2
system.
2
Fig. 17
Fig. 18
Operator manual Undercounter cooler
Energize 2-5 HC
1
2
3
31