1. General Information
1.1 Overview
Thanks for choosing Jinko Solar PV modules. In order to ensure the PV modules are installed
correctly, please read the following installation instructions carefully before modules are
installed and used.
Please remember that these products generate electricity and certain safety measures need to
be taken to avoid danger.
Make sure the module array is designed in such a way not to exceed the maximum system
voltage of any system component such as connectors or inverters.
The assembly is to be mounted over a fire resistant roof covering rated for the application.
Before mounting the module, please consult your local building department to determine
approved roofing materials.
The modules are qualified for application class A: Hazardous voltage (IEC 61730: higher than
50V DC; EN 61730: higher than 120V), hazardous power applications (higher than 240W)
where general contact access is anticipated. Modules qualified for safety through EN IEC
61730 -1 and - 2 within this application class are considered to meet the requirements for
Safety Class II.
1.2 Warnings
 PV modules generate DC electrical energy when exposed to sunlight or other light sources.
Active parts of module such as terminals can result in burns, sparks, and lethal shock.
 Artificially concentrated sunlight shall not be
directed on the module or panel.
 Front protective glass is utilized on the module.
Broken solar module glass is an electrical safety
hazard (may cause electric shock or fire). These
modules cannot be repaired and should be
replaced immediately.
 To reduce the risk of electrical shocks or burns, modules may be covered with an opaque
material during installation to avoid injury.
 The installation work of the PV array can only be done under the protection of
sun-sheltering covers or sunshades and only qualified person can install or perform
maintenance work on this module.
 Follow the battery manufacture's recommendations if batteries are used with modules.
-1-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JKM PP-60 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jinko Solar JKM PP-60 Series

  • Page 1 1. General Information 1.1 Overview Thanks for choosing Jinko Solar PV modules. In order to ensure the PV modules are installed correctly, please read the following installation instructions carefully before modules are installed and used. Please remember that these products generate electricity and certain safety measures need to be taken to avoid danger.
  • Page 2  Do not use this module to replace or partly replace roofs and walls of living buildings.  Do not install modules where flammable gas may be present.  Do not remove any part installed by Jinko Solar or disassemble the module.  All instructions should be read and understood before attempting to install, wire, operate and maintain the module.
  • Page 3: Installation Safety

    This will damage module.  Do not clean the glass with chemicals. Only use tap water. Make sure the module surface temperature is cool to the touch. Cleaning modules with cool water when module surface temp is high may result in glass breakage. ...
  • Page 4: Installation Condition

    2.2.2 Site selection In most applications, Jinko solar PV modules should be installed in a location where they will receive maximum sunlight throughout the year. In the Northern Hemisphere, the module should typically face south, and in the Southern Hemisphere, the modules should typically face north.
  • Page 5: Mechanical Installation Introduction

    ﹡ Note: 1) All installation methods herein are only for reference, and Jinko solar will not provide related mounting components, the system installer or trained professional personnel must be responsible for the PV system’s design, installation, and mechanical load calculation and security of the system.
  • Page 6 strength while meeting local code requirements. 2.3.1 Fixation with bolts For mounting with bolts, the following modules in tables 1 are applicable. The frame of each module has 8 mounting holes (Length* Width: 14mm*9mm) used to secure the modules to support structure. Always use all the eight mounting holes to secure the modules.
  • Page 7 2.3.2 Fixation with clamps The module clamps should not come into contact with the front glass and must not deform the frame. Be sure to avoid shadowing effects from the module clamps. The module frame is not to be modified under any circumstances. When choosing this type of clamp-mounting method, please be sure to use at least four clamps on each module, two clamps should be attached on each long sides of the module.
  • Page 8 2.3.2.1 Fixation with clamps on long sides of frames Dimensions(mm) Max. Test Pressure: 5400Pa (positive ) & Module type 2400Pa (negative) mechanical load 1650*992 & 1665*1002 Group 1&3 Group 2&4 1665*992 & 1684*1002 1650*992 & 1665*1002 Group 5&7 Group 6&8 1665*992 &...
  • Page 9 2.3.2.2Fixation with clamps at short sides of the frames Dimensions(mm) Max. Test Pressure: 2400Pa (positive) & 2400Pa (negative) Module type mechanical load 1650*992 Group 1 1665*1002 1665*992 Group 5 1684*1002 1956*992 Group 10 1979*1002 1987*992 Group 14 2008*1002 Table 3: Mechanical dimensions when modules installed at short side with Clamp fitting method Figure 5: Installation methods of clamps on short sides...
  • Page 10: Wiring And Connection

    Note: The installation method of clamps on short sides is based on the internal results in Jinko. The installation method of clamps on long and short sides is based on the internal results in Jinko. 3. Wiring and connection a) Before this procedure, please read the operation instructions of the PV system carefully. Make wiring by Multi-connecting cables between the PV modules in series or parallel connection, which is determined by user’s configuration requirement for system power, current and voltage.
  • Page 11: Maintenance And Care

    Figure 7: The graph of Grounding f) Follow the requirements of applicable local and national electrical codes. g) These modules contain factory installed bypass diode .If these modules are incorrectly connected to each other, the bypass diodes, cable or junction box may be damaged. h) The cable of the junction box is defined as L, as showed below in Figure 8.
  • Page 12: Inspection Of Connector And Cable

    c) No sharp objects are in contact with the PV module surfaces. d) PV modules are not shaded by unwanted obstacles and; or foreign material. e) Corrosion along the cells’ bus-bar. The corrosion is caused by moisture intrusion thought the module back sheet. Check the back sheet for damage. f) Check whether the back sheet is burn out.
  • Page 13 maintenance of photovoltaic (PV) product are beyond Jinko’s control, Jinko does not accept responsibility and expressly disclaims liability for loss ,damage, or expense arising out of or in any way connected with such installation, operation, use or maintenance. No responsibility is assumed by Jinko for any infringement of patents or other rights of third parties, which may result from use of the PV product.
  • Page 14: Appendix 1: Applicable Products

    Appendix 1: Applicable Products This document is applicable to the series of solar modules as listed below: With 6” poly and mono c-Si: Group 1 ① ② ③ JKMxxxPP JKMxxxPP-60(Plus) JKMS xxxPP-60 JKMSxxxPP-60-J ④ JKMxxxPP-60-V JKMxxxPP-60(Plus) -V JKMSxxxPP-60-V JKMSxxxPP-60-V-J ① JKMxxxPP -60B (xxx=260~290,in increment of 5)
  • Page 15 JKMSxxxM-60H-V-MX3 JKMSxxxM-60HB-V-MX3 JKMSxxxM-60H-MX3 JKMSxxxM-60HB-MX3 (xxx =270~340,in increment of 5) JKMSxxxM-60HL-V-MX3 JKMSxxxM-60HBL-V-MX3 JKMSxxxM-60HL-MX3 JKMSxxxM-60HBL-MX3 (xxx =270~340,in increment of 5) Group 9 JKMxxxM-60H-TV JKMxxxM-60HL-TV JKMxxxM-60H-T JKMxxxM-60HL-T (xxx =315~355,in increment of 5) JKMxxxN-60H-TV JKMxxxN-60HL-TV JKMxxxN-60H-T JKMxxxN-60HL-T (xxx =315~355,in increment of 5) Group 10 JKMxxxPP-72 JKMxxxPP-72(Plus) JKMSxxxPP-72...
  • Page 16 (xxx =335~395,in increment of 5) JKMSxxxM-72L-V-MX3 JKMSxxxM-72BL-V-MX3 JKMSxxxM-72L-MX3 JKMSxxxM-72BL-MX3 (xxx =335~395,in increment of 5) Group 17 JKMSxxxM-72H-V-MX3 JKMSxxxM-72HB-V-MX3 JKMSxxxM-72H-MX3 JKMSxxxM-72HB-MX3 (xxx =335~395,in increment of 5) JKMSxxxM-72HL-V-MX3 JKMSxxxM-72HBL-V-MX3 JKMSxxxM-72HL-MX3 JKMSxxxM-72HBL-MX3 (xxx =335~395,in increment of 5) Group 18 JKMxxxM-72H-TV JKMxxxM-72HL-TV JKMxxxM-72H-T JKMxxxM-72HL-T (xxx =375~425,in increment of 5) JKMxxxN-72H-TV JKMxxxN-72HL-TV...
  • Page 17 JKSN3-CCCA-xxx JKSN3-CHCA-xxx (xxx =345~370,in increment of 5) Group 29 JKMxxxM-72H-MBB-TV JKMxxxM-72H-MBB-T (xxx =385~405,in increment of 5) Group 30 JKMxxxM-60H-MBB-TV JKMxxxM-60H-MBB-T (xxx =320~335,in increment of 5) Notes:  PP: the eagle series module  Plus: the eagle+ series module  JKMS: the smart module ...
  • Page 18 Note _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ -18-...

This manual is also suitable for:

Jkm pp-60 plus seriesJkms pp-60 seriesJkms pp-60-j seriesJkm pp-60-v seriesJkm pp-60 plus v seriesJkms pp-60-v series ... Show all

Table of Contents