Rev. C 1. General Information 1.1 Overview Thanks for choosing Jinko Solar PV modules. In order to ensure the PV modules to be installed correctly, please read the following operation instructions carefully before installing and using the modules. Please remember that the products would generate electricity and certain safety measures need to be taken to avoid danger.
Page 3
Rev. C Artificially concentrated sunlight shall not be directed on the module or panel. Solar modules have a protective glass front. Broken solar module glass is an electrical safety hazard (electric shock and fire). These modules cannot be repaired and should be replaced immediately.
Rev. C Do not remove any part installed by Jinko Solar or disassemble the module. All instructions should be read and understood before attempting to install, wire, operate and maintain the module. Please don’t lift up PV modules using the attached cables or the junction box.
Rev. C rubber soles). Keep the PV module packed in the carton until installation. Do not touch the PV module unnecessarily during installation. The glass surface and the frame may be hot. There is a risk of burns and electric shock. ...
Rev. C In most applications, Jinko solar PV modules should be installed in a location where they will receive maximum sunlight throughout the year. In the Northern Hemisphere, the module should typically face south, and in the Southern Hemisphere, the modules should typically face north.
Solar PV modules can be mounted using the following methods: ﹡ Note: All installation methods herein are only for reference, and Jinko solar will not provide related mounting components, the system installer or trained professional personnel must be responsible for the PV system’s design, installation, and mechanical load calculation and security of the system.
Rev. C Figure 2 above: PV module installed with Screw fitting method* 2.3.2 Fixation with clamps (at long side or short side) The module clamps should not come into contact with the front glass and must not deform the frame. Be sure to avoid shadowing effects from the module clamps. The module frame is not to be modified under any circumstances.
Page 9
Rev. C Figure3 above: PV module installed at long side with Clamp fitting method...
Page 10
Rev. C Table 1 above: Mechanical dimensions when modules installed at long side with Clamp fitting method Figure 4 above: PV module installed at short side with Clamp fitting method...
Rev. C Table 2 above: Mechanical dimensions when modules installed at short side with Clamp fitting method 3. Wiring and connection a) Before this procedure, please read the operation instructions of the PV system carefully. Make wiring by Multi-connecting cables between the PV modules in series or parallel connection, which is determined by user’s configuration requirement for system power, current and voltage.
Page 12
Rev. C connectors is more than 10A), otherwise cables and connectors will become overheating for large current. Please pay attention: the temperature limit of cables is 85℃ and the temperature limit of connector 105℃ e) All module frames and mounting racks must be properly grounded in accordance with local and national electrical codes.
Rev. C 4. Maintenance and care a) A built up of dust or dirt on the module(s) front face will result in a decreased energy output. Clean the panel(s) preferably once per annum if possible (depend on site conditions) using a soft cloth dry or damp, as necessary. b) Never use abrasive material under any circumstances.
Page 14
Rev. C 5.1.Electrical specifications of JKM xxxM-72(xxx=160-200)Series Monocrystalline solar modules JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 160M 165M 170M 175M 180M 185M 190M 195M 200M Maximum Power at STC(Pmax) 160Wp 165Wp 170Wp 175Wp 180Wp 185Wp 190Wp 195Wp 200Wp...
Page 15
Rev. C 5.2.Electrical specifications of JKMxxxM-96(xxx=220-270)Series Monocrystalline solar modules JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 220M 225M 230M 235M 240M 245M 250M 255M 260M 265M 270M Maximum Power at 220Wp 225Wp 230Wp 235Wp 240Wp 245Wp 250Wp...
Page 16
Rev. C 5.3. Electrical specifications of JKMxxxP-60(xxx=200-250)Series polycrystalline solar modules JKM-2 JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 205P 210 P 215 P 220 P 225 P 230 P 235 P 240 P 245 P 250 P Maximum Power at 200Wp...
Page 17
Rev. C 5.4. Electrical specifications of JKMxxxM-72(xxx=250-315)Series polycrystalline solar modules JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 250M 255M 260M 265M 270M 275M 280M 285M 290M 295M 300M 305M 310M 315M Maximum Power at STC(Pmax) 250Wp 255Wp...
Page 18
Rev. C 5.5. Electrical specifications of JKMxxxP-72(xxx=250-315)Series polycrystalline solar modules JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 250P 255P 260P 265P 270P 275P 280P 285P 290P 295P 300P 305P 310P 315P Maximum Power at STC(Pmax) 250Wp 255Wp...
Page 19
Rev. C JKM-2 JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- JKM- Module Type 205M 210 M 215 M 220 M 225 M 230 M 235 M 240 M 245 M 250 M Maximum Power at 200Wp 205Wp 210Wp 215Wp 220Wp 225Wp...
Rev. C 6.Disclaimer of Liability Because the use of the manual and the conditions or methods of installation, operation, use and maintenance of photovoltaic (pv) product are beyond Jinko’s control, Jinko does not accept responsibility and expressly disclaims liability for loss ,damage, or expense arising out of or in any way connected with such installation, operation, use or maintenance. No responsibility is assumed by Jinko for any infringement of patents or other rights of third parties, which may result from use of the PV product..