CPCI Case System 6/7 U
24579-612
2.5 Power Supply
Hazardous voltage!
Parts of the power supply may be exposed with hazardous voltage. Always
remove mains/line connector before carry out any assembly work.
Caution!
Your system has not been provided with a AC power cable. Purchase a
AC power cable that is approved for use in your country. The voltage and
current rating of the AC power cable should be greater than the ratings marked
on on the product's electrical ratings label.
Power is provided through a 300 W ATX power supply with wide range input,
IEC 320-C14 connector and mains on/off switch. The power supply is located at
the front to the left of the card cage behind a front panel.
2.5.1 ATX Power Supply
Table 1: Techn. Data
Input voltage
Input frequency
Input current
Output (max)
Output (min)
Inrush Current
Efficiency
Overload protection
Overvoltage protection
Ripple
Load regulation
Hold up time
Power Good Signal
Insulation Voltage
Earth Leakage Current
Operating temperature
Derating
Storage temperature
Humidity
MTBF
Safety
EMV
Fan
Dimensions
Combined max. output current at +3.3 V and +5 V must not exceed 45 A. For
temperatures <20°C a higher min. output current is required.
2.5.2 Grounding/Earthing
Caution!
The unit is designed in accordance with protection class 1! It must therefore be
operated with protective earth/GND connection. Use only a three conductor
AC power cable with a protective earth conductor that meets the IEC safety
standards!
www.schroff.biz
90 ... 264 VAC, active PFC
47...63 Hz
5 A (115 V) / 2,5 A (230 V)
5 V / 35 A; 3,3 V / 28 A, 12 V / 22 A, -12 V / 0,8 A)
5 V / 0,5 A; 3,3 V / 0 A, 12 V / 0,5 A, -12 V / 0,0 A)
44/87 A (115/230 VAC)
>70%/75% (115/230 VAC)
110...150%, switch-off
+3,3 V (+3,9...+4,3 V), +5 V (+5,7...+6,5 V), +12 V (+13,6...+15 V)
+3,3 V 50 mV / +5 V 50 mV / +12 V 120 mV / -12 V 150 mV
+3,3 V ±5% / +5 V ±5% / +12 V +7/-5% / -12 V ±5%
>16 msec.
Power on delay 100...500 msec, Power off delay 1 msec.
Input/Chassis 3100 VDC,Input/Output 4242 VDC.
<3,5 mA (115/230 VAC)
-10...+70 °C
From 50...+70 °C 1%/°C
-20...+80 °C
10...90% RH, non-condensing
>100.000 h at +50 °C, without fan
EN 60950 / UL 60950
CE
Ball bearing fan
140 x 150 x 86 mm, ±0,5mm