Wired Remote Controller Installation - LG L8UC100BFA2 Installation Manual

Multi type
Hide thumbs Also See for L8UC100BFA2:
Table of Contents

Advertisement

Installation of Indoor, Outdoor Unit

Wired remote controller installation

• Since the room temperature sensor is in the remote controller, the remote controller box should be installed
in a place away from direct sunlight, high humidity and direct supply of cold air to maintain proper space
temperature.
Install the remote controller about 1.5m above the floor in an area with good air circulation at an average
temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote
controller LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
WIRING CONNECTION
• Remove the control box cover for electrical
connection between the indoor and outdoor
unit.
(Remove screws ➀.)
• Use the cord clamper to fix the cord.
20 Multi Type Air Conditioner
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
SUB FUNCTION
Room Temp
HI
AUTO
Heater
Preheat
MED
JET
Defrost
Humidify
LO
Filter
Out door
Time
ZONE
1 2 3 4
Timer
Operation unit
Program set
On
Off
Set no. Time
01
03
05
07
09
11
13
15
17
19
21
23
no
TIO
N
NC
B FU
hea
t
SU
r
Pre
ify
EE
D
ate
t
Hu
mid
r
SP
O
He
fros
Ou
t doo
FA
N
AUT
De
er
4
HI
JET
Filt
2
3
MP
1
m Tem
T TE
p
MED
SE
LO
23
IO
N
Roo
ZO
NE
21
AT
OP
ER
19
m
e
17
ING
Ti
set
15
SW
m
13
AU
TO
gra
Pro
11
09
uni
t
07
era
tion
05
Op
03
er
Ti
m
Of
f
e
01
On
Tim
Set
no.
no
Fig.1 Typical locations for remote controller
yes
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
SUB FUNCTION
Room Temp
HI
AUTO
Heater
Preheat
MED
JET
Defrost
Humidify
LO
Filter
Out door
Time
ZONE
1 2 3 4
Timer
Operation unit
Program set
On
Off
Set no. Time
01
03
05
07
09
11
13
15
17
19
21
23
no
5feet
(1.5meters)
Control terminal board
Control box
1
Control box cover
(On which the Electric
Wiring Connection is put)
A
A view
Remote
control cord
1
Cord clamper
Connection
cord between
the indoor unit
and the
outdoor unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L8uh100bfa2L8uc100bfa3L8uc150bfa1

Table of Contents