GATEWAY LOCATION GUIDELINES
Before selecting a final mounting location for your
Gateway, the following must be taken into considera-
tion:

Gateways should be located within 175 feet
(radially) from the intended wireless lock locations

Open areas will increase range while concrete
building construction, walls, ceilings and narrow
corridors will decrease range

ArchiTech series locks generally have shorter
range to/from a Gateway

Generally, the Gateway should be within approxi-
mately 75 feet (radially) from an AL-IME2-EXP Ex-
pander (see WI2156)

Select a location that allows access to an RJ-45 net-
work Ethernet cable connection (temporarily)

Mount Gateway within acceptable range of wire-
less router or wireless access point

Gateways should be mounted in elevated areas;
however mounting in a drop ceiling can adversely
affect signal strength

Preferred mounting position = 6 to 12" below
standard 8-9 foot ceiling

Gateways must be mounted vertically; horizontal
"flat" mounting should be specifically avoided

Although wood and wallboard construction can have
little effect upon signal strength, concrete or brick
can reduce signal strength by up to 35%. Steel-
reinforced concrete or metal lath and plaster can re-
duce signal strength as much as 90%!

Do NOT mount close to electrical wiring or other
metal obstructions such as pipes or conduits

Installing in computer closets or server rooms can
negatively impact signal strength
Helpful Tips

In difficult installations wherein signal problems
exist, the use of (multiple) AL-IME2-EXP Expand-
ers throughout the premises is recommended. AL-
IME2-EXP Expanders extend the coverage area
of version 2 Gateways, allowing control of up to its
rated maximum of 63 locks. Up to 7 Expanders
can be added to one version 2 Gateway. For more
information, see WI2156.

We recommend obtaining or creating a layout of
your intended system identifying all proposed in-
stallation locations, also noting building construc-
tion materials to assist in determining optimal
Gateway installation locations
IMPORTANT: If you plan to use AL-IME2-EXP Ex-
panders with your Gateway, be sure to read the
"EXPANDER GROUP" DIALS section on page 4
before powering your Gateway.
2
The above guidelines and tips should be followed for
each additional Gateway added to the system.

MOUNTING INSTRUCTIONS

The AL-IM2-80211 rear housing must be mounted
"up" as shown on the page 7 template; i.e. when the
front housing is attached, its engraved Networx logo
must be located at the lower right with the front hous-
ing positioned "up" in a conventional manner (the unit
contains internal antennas that must be positioned
vertically). Horizontal "flat" mounting of the enclosure
is to be specifically avoided.
Mount as follows:
1. Insert a small flat-head screwdriver into the slots at
the bottom and twist while applying inward pressure
(see Fig. 1; insert the screwdriver closer to the edg-
es of the unit, as shown in the Fig. 1 "inset" image).
Fig. 1: To separate rear housing from cover
(Inset: Insert flat-head screwdriver closer to the edges of the unit)
2. Using the rear housing as a mounting template, se-
cure the unit to a wall or other flat surface using the
hardware provided (see page 7 for printed tem-
plate).
Shown in Fig. 2, the rear housing includes two
mounting holes for single-gang (A) and four mount-
ing holes for double-gang (B) electrical utility boxes,
as well as four all-purpose holes (C) for mounting to
drywall or other surfaces (use minimum #6 screws
suitable for the surface).
C
C
Fig. 2: Rear housing mounting holes for single-gang (A) and
double-gang (B) electrical boxes, and four all-purpose holes (C)
(Inset image)
B
A
B
C
C
B
A
B