To ensure stability the appliance should be located on a flat, level surface, correctly loaded with the castors
locked.
If the supply cord is damaged, it must be replaced by the manufacturer, it's service agent or similarly qualified
persons in order to avoid hazards.
Care should be taken to avoid prolonged contact with cold surfaces with unprotected body parts, Correct PPE to
be used at all time.
When moving the appliance appropriate gloves should be worn, and a relevant risk assessmeny carried out.

Disposal Requirements

If not disposed of properly all refrigerators have components that can be harmful to the environment. All
old refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in
accordance with national laws and regulations.
Start-Up and Operation
After unpacking leave to stand for 60 minutes and clean before turning on (cleaning directions are supplied
within this manual). Position the Multideck with care on a level, flat, solid surface area.
Avoid cold air from air conditioning units & direct sunlight as these factors will affect the units' performance.
Warm air is produced from the rear of the unit & for this reason please leave a breathing area around the unit
as follows:
Each Side of the Unit to Wall or next Unit.
Top of Unit to Ceiling (No Rear Ventilation)*
Top of Unit to Ceiling (With Rear Ventilation)
Rear of Units Wall Spacer to Wall
Rear of Units Wall Spacer to Wall
*When positioned into a recess or similar small area.
Insert the mains plug into the wall socket and switch on. Please do not plug or unplug the unit with wet hands.
The Multideck will start automatically, displaying the actual internal temperature of the unit (area where
product is displayed). All models are pre-set at +3° C to +5°C, so no adjustments are required.
Allow the Multideck to reach its normal operating temperature before loading.
With an interruption to the main power supply, the Multideck will re-start automatically after power is restored.
The vaporiser tray (at the base of the unit) may overflow during a power cut but this is dependent on the length
of time the power is off.
Standby
Pressing this button for 3 seconds will allow the unit to be turned on or put into standby.
Display Icons and Switches
2
Gap
Position
Function Icons
Temperature Display
Gap
Measurement
10mm
80mm
10mm
60mm
20mm
Buttons/Switches
Relevant
Models
Slim & Pro
Slim & Pro
Slim & Pro
Slim
Pro

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slim 900 ngSlim 1200 ngSlim 1500 ngSlim 1800 ngSlim 700 rfSlim 900 rf ... Show all

Table of Contents