Page 2
1. Ensure that wherever possible waste is removed from the client’s site, where arrangements are in place all waste should be returned to Foster Refrigerator’s premises. In certain circumstances waste may be disposed of on the clients site; if permission is given, if the client has arrangements in place for the type of waste.
Cabinet Description Controls located in the unit cover. All of the cabinet range incorporates bottom mounted refrigeration systems with the evaporator located on the back wall. The refrigerant used is R404a. Door operated fan switches stop the fans when the door is opened. FXBC10, FXBC 20, FXBC30 all 230/1/50Hz 13amp FXBC40 230/1/50Hz 16amp.
Page 4
Controller operation Prior to starting a chill operation ensure the controller is in the ‘stand-by’ mode. Timed chill operation To place the controller in ‘stand–by’ press for 2 seconds, whilst in stand-by the cabinet internal air temperature will be displayed intermittently. Press ‘PoS’...
Page 5
Defrost Defrost will be initiated automatically in the hold mode at pre-set intervals. To initiate a manual defrost during the hold mode press for 5 seconds, defrost will start with being displayed. Alarm and Warnings Defrost in operation Low Temperature Alarm High Temperature Alarm Air Probe fault Food Probe Fault...
Page 6
Access to the second level To access the parameters the controller must be in the stand-by mode. To place the controller in ‘stand–by’ press for 2 seconds, whilst in stand-by the cabinet internal air temperature will be displayed intermittently. Press for 4 seconds the display will show ‘PA’.
Defrost interval (0 = defrost not active) hrs. Defrost duration (0 = defrost not active) min. Drip time duration min. Minimum temp alarm 99.0 °C Minimum temp alarm type (depends on 'r9' & 'rA' [or 'r9-A1' and 0 (NO flag 'rA-A1']) Alarm) Maximum temp alarm...
Spare Parts List ITEM DESCRIPTION PART NUMBER MODEL Controller EVK802 00-555941 All Models Air Probe ECSND0112A 00-555942 All Models Food Probe ECSNDX0008 00-555943 All Models Compressor MX16TB 00-555674 FXBC10 Compressor CAJ9513Z 00-554334 FXBC20 Compressor MS26TB 00-555682 FXBC30 Compressor MS34TB 00-555677 FXBC40 Condenser Fan Motor Grid Mount 16W...