Fostex FD-4 Service Manual page 23

Digital multitracker
Hide thumbs Also See for FD-4:
Table of Contents

Advertisement

8)
Connect the 50-pin flat cable between J12 of MAIN PCB assy and the HDD connectors. When connecting, in order to
connect pins straight, do not twist or turn the cable. (Pin-1 of J12 (RED) must go to Pin-1 of HDD connectors.)
9)
Connect the following cables from the connectors on the MAIN PCB assy.
• 9-pin cable to the J3 (coming from MIXER A PCB assy)
• 9-pin cable to the J7 (coming from DISPLAY PCB assy)
• 7-pin cable to the J10 (coming from MIXER A PCB assy)
10)
Tighten 14 x screws (BBT 3 x 8 BZn) which fix the FD-4 Top Panel section to the Bottom Panel section.
BBT 3 x 8 BZn
RED
Cable assy, flat, 50P,
P1.0, AMPMOD,
L150
BBT 3 x 8 BZn
FD-4
23