Viessmann Vitodens 200-W B2HA Application Manual page 17

Residential boiler
Hide thumbs Also See for Vitodens 200-W B2HA:
Table of Contents

Advertisement

Vitodens 200-W, Technical Data
Product Information
B
o
l i
r e
M
o
d
l e
N
. o
B
2
H
A
Dimensions
Overall depth
Overall width
Overall height *8
Flue gas *4
Temperature (at boiler return
temperature of 86ºF (30ºC)
- at rated full load
- at rated partial load
Temperature (at boiler return
temperature of 140ºF (60ºC)
Max. condensate flow rate *5
for NG and LPG
T
/T
=104/86ºF (40/30ºC)
S
R
Condensate connection *6
Boiler flue gas connection *7
Combustion air supply
connection (coaxial)
Sound Rating
- at maximum input
- at minimum input
*A
For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 88,100 and 150
will have an altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m) average of 2.8%
/ 1,000 ft. (305 m).
*B The input for model B2HA 112 at 10,000 ft. (3000 m) will have an input de-rate of 13%.
*4
Measured flue gas temperature with a combustion air temperature of 68°F (20°C).
*5
Based on maximum input rate.
*6
Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200-W, B2HA for details.
*7
For side wall vent installations (coaxial system):
Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200-W, B2HA
Venting System.
Side wall co-axial vent installation must include Viessmann protective screen!
For details refer to the Installation Instructions for the Vitodens 200-W, B2HA Venting System.
The Vitodens 200-W can only be common vented with other Vitodens 200-W boilers of the same size and series.
For details refer to the Common Venting Manual.
*8
Add approximately 2½ inches (65 mm) for coaxial vent pipe transition adaptor.
For information regarding other Viessmann System Technology componentry, please reference the documentation
of each respective product.
A
8
8
*
inches
21
(mm)
(530)
inches
19
mm)
(480)
inches
43 ½
mm)
(1105)
ºF (ºC)
135 57)
ºF (ºC)
99 37)
ºF (ºC)
162 72)
USG/h
3.1
(L/h)
(11.7)
hose
nozzle
Ø in.
¾-
1
Ø
in. (mm)
4
/
(110)
3
8
outer
Ø in. (mm)
6 (150)
dB
69
dB
38
100 * A
112 * B
21
27.1
(530)
(698)
19
23
/
5
8
(480)
(600)
43 ½
44 ½
(1105)
(1128)
135 (57)
124 (51)
99 (37)
102 (39)
162 (72)
158 (70)
3.5
4.35
(13.1)
(16.5)
¾-
¾-
1
1
4
/
(110)
4
/
(110)
3
3
8
8
6 (150)
6 (150)
69
57
38
40
150 * A
27.1
(698)
23
/
5
8
(600)
44 ½
(1128)
140 (60)
102 (39)
165 (74)
5.28
(20.0)
¾-
1
4
/
(110)
3
8
6 (150)
61
40
13

Hide quick links: