Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-11
MIL-STD-810F 509.4
IEC 60068-2-14
IEC 60068-2-18
IEC 529 (IP65/IP67)
IEC 60068-2-6
IEC 60068-2-64
IEC 60068-2-29
34
Description
Low Temperature
High Temperature
Salt Fog
Temperature Change
Water (Rain, Intensity)
Water (Rain)
Sine Vibration
Random Vibration (Class 4M5)
Random Vibration
Shock (Class 4M5)
Shock
https://support.industry.siemens.com/cs/ww/en/
-25 °C for 72 hours
-40 °C (-40 °F) for 16 hours
-40 °C (-40 °F) for 72 hours
55 °C (131 °F) for 72 hours
60 °C (140 °F) for 16 hours
70 °C (158 °F) for 72 hours
-10 to 45 °C (14 to 113 °F) @ 0.5 °C/min (0.9 °F/min) for 2 cycles
-40 to -30 °C (-40 to -22 °F) @ 1 °C/min (1.8 °F/min) for 5 cycles
0.01 m³/min (0.35 ft³/min @ 90 kPa (13 PSI) for 30 minutes
0.01 m³/min @ 90 kPa (13 PSI) for 15 minutes
Displacement: 1.5 mm
Acceleration: 2 m/s²
Frequency Range: 5 to 62 Hz, 62 to 200 Hz
Duration: 3x5 sweep
Frequency Range: 5 to 10 Hz, 10 to 50, 50 to 100 Hz
3 axes, 30 min per axes
Frequency Range: 5 to 20 Hz, 20 to 200 Hz
3 axes, 30 min per axes
Spectrum: Half sine
Accelerator: 50 m/s²
100 shocks in each direction
Spectrum: Half sine
Accelerator: 180 m/s²
RUGGEDCOM WIN5214
Installation Guide
Test Levels
5% NaCI 35° 48h
Velocity: 5 mm/s
3 Axes
ASD: 0.04 m²/s³
12 to 12 dB/oct
ASD: 1 m²/s³
-3 dB/oct
Duration: 11 ms
Duration: 6 ms
Environmental Type Tests